IDEAS home Printed from https://ideas.repec.org/a/taf/gcmbxx/v24y2021i12p1294-1301.html
   My bibliography  Save this article

Influence of renal artery stenosis morphology on hemodynamics

Author

Listed:
  • Zhuxiang Xiong
  • Ding Yuan
  • Jiarong Wang
  • Tinghui Zheng
  • Yubo Fan

Abstract

ObjectiveCurrently, the clinical classification of the severity of renal artery stenosis (RAS) solely depends on the degree of stenosis. In addition, when the stenosis degree is between 50% and 70%, the clinical strategy is decided based on whether the RAS is hemodynamically significant. In this study, the influence of RAS morphological parameters on hemodynamics was numerically analyzed to provide a theoretical basis for clinical treatment.MethodsIdealized RAS models were established to investigate the hemodynamic effects of the stenosis length, asymmetric stenosis, and direction of the opening of the renal artery.ResultsThe longer the stenosis length, the greater is the ratio of the low time-averaged wall shear stress (WSS) and high oscillatory shear index (OSI) area distal stenosis (when the stenosis area is the same). In addition, asymmetric stenosis leads to a significant increase in the ratio of the renal artery peak systolic velocity (R-PSV) and the abdominal aorta peak systolic velocity (A-PSV) when the stenosis area is 60–70%. Furthermore, the fraction flow reserve (FFR) of the RAS model with 12 mm stenosis length, upward eccentricity and upward direction of renal artery opening was approximately equal to the cumulative value of the influence of different stenosis morphologies on FFR.ConclusionAn assessment of the severity of RAS should consider the stenosis area and other morphological parameters, including the length and asymmetry of RAS as well as the direction of the opening of renal artery, particularly when the stenosis degree of RAS is between 50% and 70%.

Suggested Citation

  • Zhuxiang Xiong & Ding Yuan & Jiarong Wang & Tinghui Zheng & Yubo Fan, 2021. "Influence of renal artery stenosis morphology on hemodynamics," Computer Methods in Biomechanics and Biomedical Engineering, Taylor & Francis Journals, vol. 24(12), pages 1294-1301, October.
  • Handle: RePEc:taf:gcmbxx:v:24:y:2021:i:12:p:1294-1301
    DOI: 10.1080/10255842.2021.1883592
    as

    Download full text from publisher

    File URL: http://hdl.handle.net/10.1080/10255842.2021.1883592
    Download Restriction: Access to full text is restricted to subscribers.

    File URL: https://libkey.io/10.1080/10255842.2021.1883592?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    More about this item

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:taf:gcmbxx:v:24:y:2021:i:12:p:1294-1301. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Chris Longhurst (email available below). General contact details of provider: http://www.tandfonline.com/gcmb .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.