Author
Abstract
The goal of this work was to use finite element analysis (FEA) to evaluate the primary stability of the dental implant without further in vivo measurements. Through proper simulations the information about stability could be obtained faster and easier than in vitro or in vivo studies. Four dental implants were chosen to evaluate their implant stability in various grades of bone. The 3D CAD models of these implants were reengineered via stereo microscopic measurements and the reengineered models were placed in artificial bone samples. Our approach was to simulate the micro mobility with FEA in various types of dental implants to see the differences between them and to convert the simulated micro mobility to Implant Stability Quotient (ISQ). The ISQ was chosen as the representation of implant stability because it is a general index-number of implant stability and it could also be measured with a standard commercially available device in clinics. After performing the simulations, the effect of the predrilling procedures on one exact implant type was investigated. Due to the numerous simulations it can be concluded that the implant stability (ISQ) can be effectively simulated via FEA, moreover the behavior of different implants in different type of surrounding bone tissues can also be evaluated. With this method it is possible to predict and to monitor the stability of known and also of novel dental implants before implantation.
Suggested Citation
Dávid Pammer, 2019.
"Evaluation of postoperative dental implant primary stability using 3D finite element analysis,"
Computer Methods in Biomechanics and Biomedical Engineering, Taylor & Francis Journals, vol. 22(3), pages 280-287, February.
Handle:
RePEc:taf:gcmbxx:v:22:y:2019:i:3:p:280-287
DOI: 10.1080/10255842.2018.1552682
Download full text from publisher
As the access to this document is restricted, you may want to
for a different version of it.
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:taf:gcmbxx:v:22:y:2019:i:3:p:280-287. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Chris Longhurst (email available below). General contact details of provider: http://www.tandfonline.com/gcmb .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.