IDEAS home Printed from https://ideas.repec.org/a/taf/gcmbxx/v18y2015i3p223-232.html
   My bibliography  Save this article

Behaviour of orthotropic surgical implant in hernia repair due to the material orientation and abdomen surface deformation

Author

Listed:
  • Izabela Lubowiecka

Abstract

Surgical implants used in hernia repair reveal isotropic as well as orthotropic properties. In particular, its orthotropy, in relation to the different range of typical deformations observed in different directions and zones of abdomen surface due to the patients' life activities, has a significant influence on the extreme junction forces in the mesh–tissue connections and hence the repair persistence. The finite element model of the orthotropic implant was developed, and the junction forces in the connections of tissue and mesh were studied. The kinematical extortions representing the abdomen surface deformations identified in specific zones of hernia placement were applied to the model. The sensitive analysis was applied to specify the influence of the orthotropy (implant orientation) direction to the repair persistence. Due to the anisotropy of the human abdomen and also the different range of deformations observed in different areas of abdomen surface, the behaviour of the implant differs significantly depending on the hernia placement and the implant orientation. Especially, it is observed in the values of the implant–tissue junction forces which determinate considerably the repair persistence. The provided results and conclusions may be useful in some clinical recommendations for implantation of orthotropic surgical mesh specifying the hernia placement as well as the orthotropic implant orientation. This can also be considered in the design of new synthetic implants with more physiologic tissue-like properties also taking into account the human abdomen anisotropy.

Suggested Citation

  • Izabela Lubowiecka, 2015. "Behaviour of orthotropic surgical implant in hernia repair due to the material orientation and abdomen surface deformation," Computer Methods in Biomechanics and Biomedical Engineering, Taylor & Francis Journals, vol. 18(3), pages 223-232, February.
  • Handle: RePEc:taf:gcmbxx:v:18:y:2015:i:3:p:223-232
    DOI: 10.1080/10255842.2013.789102
    as

    Download full text from publisher

    File URL: http://hdl.handle.net/10.1080/10255842.2013.789102
    Download Restriction: Access to full text is restricted to subscribers.

    File URL: https://libkey.io/10.1080/10255842.2013.789102?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    More about this item

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:taf:gcmbxx:v:18:y:2015:i:3:p:223-232. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Chris Longhurst (email available below). General contact details of provider: http://www.tandfonline.com/gcmb .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.