IDEAS home Printed from https://ideas.repec.org/a/spr/drugsa/v44y2021i1d10.1007_s40264-020-01022-2.html
   My bibliography  Save this article

Frequency and Associated Costs of Anaphylaxis- and Hypersensitivity-Related Adverse Events for Intravenous Iron Products in the USA: An Analysis Using the US Food and Drug Administration Adverse Event Reporting System

Author

Listed:
  • Henry Trumbo

    (St. Mary Medical Center)

  • Karolina Kaluza

    (American Regent)

  • Syed Numan

    (American Regent)

  • Lawrence T. Goodnough

    (Stanford University)

Abstract

Introduction and Objective Intravenous iron preparations rapidly correct iron deficiency anemia, with the notable drug class effect of rare, yet potentially life-threatening, administration-related hypersensitivity or anaphylactic reactions. The objective of this comparative study was to assess adverse events associated with four intravenous iron preparations and estimated medical costs, in the US Food and Drug Administration Adverse Event Reporting System (FAERS) database. Methods Cases of hypersensitivity reactions and anaphylaxis/anaphylactic shock associated with iron dextran, iron sucrose, ferumoxytol, and ferric carboxymaltose, spontaneously reported to FAERS (1 January, 2014 to 31 December, 2019), were extracted. The reporting odds ratio lower bound 90% confidence interval (ROR05) > 1 and cases ≥ 5 defined a likely signal for a drug–adverse event association. Adverse event-associated medical costs were estimated using Agency for Healthcare Research and Quality/Healthcare Cost and Utilization Project 2016 data. Results For hypersensitivity reactions, ferumoxytol and iron dextran had the highest ROR05 values (5.00 and 4.35, respectively) and greatest proportions of associated deaths (7.1% and 5.3%), followed by iron sucrose (ROR05 3.94, deaths 2.4%), and ferric carboxymaltose (ROR05 3.03, deaths 0.2%). For anaphylaxis/anaphylactic shock, ROR05 for cases/deaths were: 39.32/13.4%, ferumoxytol; 37.80/4.5%, iron dextran; 17.60/4.7%, iron sucrose; and 8.77/no deaths, ferric carboxymaltose. Downstream medical costs per adverse event were highest with iron dextran (US$8615) and ferumoxytol (US$8164), followed by iron sucrose (US$4212), and ferric carboxymaltose (US$1832). Conclusions Reporting rates of hypersensitivity and anaphylaxis with intravenous iron preparations were highest with ferumoxytol and lowest with ferric carboxymaltose in the US FAERS database. Adverse event-related medical costs were highest for iron dextran and ferumoxytol, and lowest for ferric carboxymaltose.

Suggested Citation

  • Henry Trumbo & Karolina Kaluza & Syed Numan & Lawrence T. Goodnough, 2021. "Frequency and Associated Costs of Anaphylaxis- and Hypersensitivity-Related Adverse Events for Intravenous Iron Products in the USA: An Analysis Using the US Food and Drug Administration Adverse Event," Drug Safety, Springer, vol. 44(1), pages 107-119, January.
  • Handle: RePEc:spr:drugsa:v:44:y:2021:i:1:d:10.1007_s40264-020-01022-2
    DOI: 10.1007/s40264-020-01022-2
    as

    Download full text from publisher

    File URL: http://link.springer.com/10.1007/s40264-020-01022-2
    File Function: Abstract
    Download Restriction: Access to the full text of the articles in this series is restricted.

    File URL: https://libkey.io/10.1007/s40264-020-01022-2?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    More about this item

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:spr:drugsa:v:44:y:2021:i:1:d:10.1007_s40264-020-01022-2. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Sonal Shukla or Springer Nature Abstracting and Indexing (email available below). General contact details of provider: http://www.springer.com/economics/journal/40264 .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.