IDEAS home Printed from https://ideas.repec.org/a/spr/aphecp/v16y2018i2d10.1007_s40258-017-0354-6.html
   My bibliography  Save this article

ENDURALIFE-Powered Cardiac Resynchronisation Therapy Defibrillator Devices for Treating Heart Failure: A NICE Medical Technology Guidance

Author

Listed:
  • James Michael Evans

    (Cardiff University)

  • Andrew Cleves

    (Cedar Healthcare Technology Research Centre)

  • Helen Morgan

    (Cardiff University)

  • Liesl Millar

    (National Institute for Health and Care Excellence)

  • Grace Carolan-Rees

    (Cedar Healthcare Technology Research Centre)

Abstract

ENDURALIFE™-powered cardiac resynchronisation therapy defibrillator (CRT-D) devices were the subject of an evaluation by the National Institute for Health and Care Excellence, through its Medical Technologies Evaluation Programme, for the treatment of heart failure. Boston Scientific (manufacturer) submitted a case for the adoption of the technology, claiming that it has a longer battery life resulting in a longer time to CRT-D replacement. Other claimed benefits were fewer complications associated with replacement procedures, fewer hospital admissions, less time spent in hospital and reduced demand on cardiology device implantation rooms. The submission was critiqued by Cedar, an external assessment centre. The submitted clinical evidence showed that ENDURALIFE-powered devices implanted during the period 2008–2010 were superior, in terms of longevity, to other devices at that time. Submitted economic evidence indicated that, because of a reduction in the need for replacement procedures, ENDURALIFE-powered devices were cost saving when compared to comparator devices. Cedar highlighted uncertainty of the applicability of the clinical evidence to devices marketed today. The Medical Technologies Advisory Committee noted that this was unavoidable due to the follow-up time required to study battery life. Clinical experts noted that increased battery life is an important patient benefit. However, centres use devices from multiple manufacturers to negate pressure on clinical services in the event of a major device recall. The clinical and economic evidence showed benefits to the patient, and further analysis requested by the committee suggested that ENDURALIFE-powered CRT-Ds may save between £2120 and £5627 per patient over 15 years through a reduction in the need for replacement procedures. ENDURALIFE-powered CRT-D devices received a positive recommendation in Medical Technologies Guidance 33.

Suggested Citation

  • James Michael Evans & Andrew Cleves & Helen Morgan & Liesl Millar & Grace Carolan-Rees, 2018. "ENDURALIFE-Powered Cardiac Resynchronisation Therapy Defibrillator Devices for Treating Heart Failure: A NICE Medical Technology Guidance," Applied Health Economics and Health Policy, Springer, vol. 16(2), pages 177-186, April.
  • Handle: RePEc:spr:aphecp:v:16:y:2018:i:2:d:10.1007_s40258-017-0354-6
    DOI: 10.1007/s40258-017-0354-6
    as

    Download full text from publisher

    File URL: http://link.springer.com/10.1007/s40258-017-0354-6
    File Function: Abstract
    Download Restriction: Access to the full text of the articles in this series is restricted.

    File URL: https://libkey.io/10.1007/s40258-017-0354-6?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    More about this item

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:spr:aphecp:v:16:y:2018:i:2:d:10.1007_s40258-017-0354-6. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Sonal Shukla or Springer Nature Abstracting and Indexing (email available below). General contact details of provider: http://www.springer.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.