IDEAS home Printed from https://ideas.repec.org/a/spr/aphecp/v11y2013i1p5-13.html
   My bibliography  Save this article

Pipeline™ Embolization Device for the Treatment of Complex Intracranial Aneurysms

Author

Listed:
  • Kathleen Withers
  • Grace Carolan-Rees
  • Megan Dale

Abstract

As part of its Medical Technologies Evaluation Programme, the National Institute of Health and Clinical Excellence (NICE) invited the manufacturer, Covidien, to provide clinical and economic evidence for the evaluation of the Pipeline™ embolization device (PED) for the treatment of complex intracranial aneurysms. Cedar; a consortium between Cardiff and Vale University Health Board and Cardiff University, was commissioned to act as an External Assessment Centre (EAC) for NICE to independently critique the manufacturers’ submissions. This article gives an overview of the evidence provided, the findings of the EAC and the final guidance published by NICE. The scope issued by NICE considered PED as the intervention in a patient population with complex unruptured intracranial aneurysms (IAs), specifically large/giant, wide-necked and fusiform aneurysms. The comparator treatments identified were stent-assisted coiling, parent vessel occlusion, neurosurgical techniques and conservative management. The manufacturer claimed that PED fulfils a currently unmet clinical need in the treatment of large or giant, wide-necked or fusiform IAs. Thirteen studies were identified by the manufacturer as being relevant to the decision problem, with two of these included for data extraction. The EAC identified 16 studies as relevant, three of which had been published after the manufacturer’s search. Data extraction was carried out on these studies as, although many were low level research comprising of case reports and case series, they provided useful, pertinent safety and outcome data. No relevant economic studies of the device were identified; therefore, a new economic model was designed by the manufacturer. The base-case scenario provided recognized the costs of PED to be higher than the costs for endovascular parent vessel occlusion, neurosurgical parent vessel occlusion, neurosurgical clipping and conservative management. However, PED was found to be cost saving compared with stent-assisted coiling, with a saving of £13,110 per patient. Analysis of the clinical data suggested that treatment with PED has high rates of clinical success with high rates of aneurysm occlusion and acceptable adverse events for the patient population. Economic evidence suggested that the costs in the base-case for PED may have been underestimated, meaning that PED would only become cost saving in patients who would otherwise require treatment with 32 coils or more. NICE Medical Technologies Guidance MTG10, issued in May 2012, recommends the adoption of PED in selected patients within the UK National Health Service (NHS). Copyright The Author(s) 2013

Suggested Citation

  • Kathleen Withers & Grace Carolan-Rees & Megan Dale, 2013. "Pipeline™ Embolization Device for the Treatment of Complex Intracranial Aneurysms," Applied Health Economics and Health Policy, Springer, vol. 11(1), pages 5-13, February.
  • Handle: RePEc:spr:aphecp:v:11:y:2013:i:1:p:5-13
    DOI: 10.1007/s40258-012-0005-x
    as

    Download full text from publisher

    File URL: http://hdl.handle.net/10.1007/s40258-012-0005-x
    Download Restriction: Access to full text is restricted to subscribers.

    File URL: https://libkey.io/10.1007/s40258-012-0005-x?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Iain Willits & Kim Keltie & Joyce Craig & Andrew Sims, 2014. "WatchBP Home A for Opportunistically Detecting Atrial Fibrillation During Diagnosis and Monitoring of Hypertension: A NICE Medical Technology Guidance," Applied Health Economics and Health Policy, Springer, vol. 12(3), pages 255-265, June.

    More about this item

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:spr:aphecp:v:11:y:2013:i:1:p:5-13. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Sonal Shukla or Springer Nature Abstracting and Indexing (email available below). General contact details of provider: http://www.springer.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.