Author
Listed:
- Sourov Das
- Simran Patra
- Shubham Om
- Sushmita Kundu
Abstract
Background: Routine clinical breast examination (CBE) services contribute to breast cancer early-detection activities in Bangladesh, but national program performance and reporting completeness are poorly characterized. We assessed reported CBE activity, geographic variation, positivity, reporting completeness, and temporal trends from 2019 through 2025. Methods: We retrospectively analyzed routine CBE program data from 1,209 location-specific eligible facilities across Bangladesh from January 2019 through December 2025. Because individual-level identifiers were unavailable, records were analyzed as CBE events rather than unique women screened. Reported CBE examination rates used estimated populations of women aged 30–69 years, with district denominators proportionally allocated using census-based population distributions. Reporting completeness was defined as submitted facility-month reports divided by expected reports. Interrupted time-series regression assessed changes associated with March 2020 using calendar-month fixed effects and heteroskedasticity- and autocorrelation-consistent standard errors. Results: A total of 3,193,080 reported CBE events were recorded. The reported examination rate increased from 0.3% in 2019 to 2.4% in 2023, then declined to 1.8% in 2024 and 1.1% in 2025. In 2025, division-level rates ranged from 0.7% to 1.7% and district-level rates from 0.2% to 2.8%. Overall positivity was 1.0% (31,624 positive events), reaching 1.6% in 2025. Mean annual reporting completeness rose from 12.1% in 2019 to 42.2% in 2024 and was 39.7% in 2025; no month reached 60% national completeness. Interrupted time-series analysis found no significant immediate level change (14,416 events; 95% CI −7,438–36,269; P = 0.196) or post-intervention slope change (−375 events/month; 95% CI −1,673–923; P = 0.571). Conclusions: Reported CBE activity expanded through 2023 but subsequently declined, with marked geographic variation and persistently incomplete reporting. These findings describe reported program activity rather than true population screening coverage. Strengthening routine reporting, individual-level tracking, quality assurance, and referral follow-up is needed for more reliable program evaluation.
Suggested Citation
Sourov Das & Simran Patra & Shubham Om & Sushmita Kundu, 2026.
"Reported clinical breast examination activity in Bangladesh, 2019–2025: Temporal trends, geographic variation, positivity, and reporting completeness,"
PLOS ONE, Public Library of Science, vol. 21(10), pages 1-17, October.
Handle:
RePEc:plo:pone00:0361910
DOI: 10.1371/journal.pone.0361910
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0361910. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.