Author
Listed:
- Ai Cao My Bui
- Quynh Tran Nhat Nguyen
- Anh Ngoc Minh Bui
- Minh Vu Phuc Ha
- Nhan Phu Nguyen
- Thy Ha Anh Nguyen
- Nhan Quoc Dang
- Phuong Minh Tran
- Tu Vu Kha
- Nhu Dong Phuong Nguyen
- Liem Diep Bao Le
- Huy Hoai Tran
- Dung The Bui
- Nghia Phu Nguyen
Abstract
Background: Ambulatory blood pressure monitoring (ABPM) is the reference standard for diagnosing hypertension (HTN), but its use in routine practice remains limited because of cost, availability, and patient burden. Automated office blood pressure (AOBP) has been proposed as a practical alternative, although its performance relative to ABPM remains uncertain. Objectives: To evaluate the agreement and diagnostic performance of 30-minute AOBP compared with 24-hour ABPM and to identify optimal cut-off values for detecting ambulatory hypertension. Methods: In this prospective cohort study, 79 adults undergoing ABPM also underwent 30-minute AOBP measurement with automated readings every 5 minutes. The mean of the final six measurements was analyzed. Agreement was assessed using paired comparisons and Bland–Altman analysis. Diagnostic performance using receiver operating characteristic (ROC) analysis and agreement statistics. Results: Thirty-minute AOBP values were consistently higher than ABPM measurements. Mean differences were +6.59/ + 7.27 mmHg for systolic/diastolic BP versus 24-hour ABPM and +3.73/ + 5.16 mmHg versus daytime ABPM (all p
Suggested Citation
Ai Cao My Bui & Quynh Tran Nhat Nguyen & Anh Ngoc Minh Bui & Minh Vu Phuc Ha & Nhan Phu Nguyen & Thy Ha Anh Nguyen & Nhan Quoc Dang & Phuong Minh Tran & Tu Vu Kha & Nhu Dong Phuong Nguyen & Liem Diep , 2026.
"Compare 30-minute automated office blood pressure vs 24-hour ambulatory blood pressure monitoring: A prospective study,"
PLOS ONE, Public Library of Science, vol. 21(11), pages 1-16, November.
Handle:
RePEc:plo:pone00:0360957
DOI: 10.1371/journal.pone.0360957
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0360957. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.