Author
Listed:
- Jafar Keighobadi
- Farnaz Imani
Abstract
Developments in atomic rate sensors have opened new opportunities for achieving high-precision rate integration. This study investigates the measurement principles and calibration parameters of an atomic interferometry (AI) rotation-rate sensor, modeled through Raman beam interactions and validated using real trajectory data. The primary objective is to identify and estimate the sensor parameters in order to improve orientation accuracy. To this end, real test data were collected from GPS-aided inertial systems (AIDIS 16407 and Vitans) along a predefined route. These data were incorporated into a software-in-the-loop AI gyroscope model, in which Raman laser beams acted as the excitation signal. A two-stage cascaded Extended Kalman Filter (EKF) was developed to simultaneously estimate sensor bias and calibration parameters. This approach enables parameter identification without requiring a physical AI gyroscope, thereby providing a cost-effective calibration framework. The experimental results demonstrate a significant reduction in bias uncertainty from 10−6 to 10−10 rad/s, along with a 35% improvement in orientation accuracy compared to the uncalibrated case. Furthermore, the calibrated AI parameters were applied to Raman spectroscopy of Rubidium (Rb), where an optimal wavelength of 1100 nm increased the Raman peak intensity by 20%, enhancing molecular bond resolution and spectral clarity.These findings confirm that the proposed calibration approach not only improves navigation accuracy but also enhances Raman spectroscopic analysis, highlighting the interdisciplinary potential of AI-based sensors.
Suggested Citation
Jafar Keighobadi & Farnaz Imani, 2026.
"Calibration and sensitivity enhancement of AI rate integrator through EKF and impact on raman spectroscopy optimal wavelengths,"
PLOS ONE, Public Library of Science, vol. 21(6), pages 1-26, June.
Handle:
RePEc:plo:pone00:0351113
DOI: 10.1371/journal.pone.0351113
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0351113. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.