Author
Listed:
- Sunee Chansangpetch
- Phichayut Phinyo
- Jayanton Patumanond
- Janejit Choovuthayakorn
- Shan C Lin
Abstract
Purpose: To develop predictive models using three-dimensional (3D) and conventional two-dimensional (2D) anterior-segment optical coherence tomography (AS-OCT) parameters for intraocular pressure (IOP) reduction following phacoemulsification in glaucoma and non-glaucoma cohorts. Methods: This prospective study included patients with and without glaucoma who underwent phacoemulsification. Preoperative predictors of 1-month IOP reduction, including clinical, ocular biometry, and AS-OCT (CASIA2) parameters, were analyzed. 3D AS-OCT measurements were assessed in two approaches: (1) averaging 360-degree values and (2) estimating circumferential areas or volumes. 2D variables were obtained from horizontal cross-sectional images. Model selection with least absolute shrinkage and selection operator (LASSO) for 2D and 3D variables was performed separately. R-squared (R²) used to represent model accuracy. The performance was validated by bootstrap resampling. Results: A total of 130 eyes (64 glaucoma, 66 non-glaucoma) from 103 patients were included. The average IOP change was −1.20 ± 3.29 mmHg. Preoperative IOP (preIOP) was the strongest single predictor across all models. In the entire cohort, the final models showed moderate predictability (R² 38% for 3D and 36% for 2D; optimism-corrected R² 31% for both). In glaucoma eyes, models incorporating AS-OCT angle status and anterior chamber width achieved R² values of 36% (3D) and 38% (2D), with optimism-corrected R² of 27% (3D) and 28% (2D). In non-glaucoma eyes, both 3D and 2D models showed higher predictability (R² 53%, optimism-corrected R² 45%), with final predictors incorporating AS-OCT anterior chamber area and iris thickness. Both 3D and 2D models significantly outperformed the reference preIOP models across all cohorts (all p > 0.05). Conclusions: AS-OCT parameters improved the predictability of IOP reduction after phacoemulsification, with notably better performance in non-glaucoma eyes. 2D and 3D models showed comparable predictive ability.
Suggested Citation
Sunee Chansangpetch & Phichayut Phinyo & Jayanton Patumanond & Janejit Choovuthayakorn & Shan C Lin, 2026.
"Comparable performance of 3D and 2D anterior segment optical coherence tomography in predicting intraocular pressure reduction following cataract surgery,"
PLOS ONE, Public Library of Science, vol. 21(3), pages 1-18, March.
Handle:
RePEc:plo:pone00:0345582
DOI: 10.1371/journal.pone.0345582
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0345582. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.