Author
Listed:
- Jessica V Eberle
- Sebastian Bickelhaupt
- Lorenz A Kapsner
- Sabine Ohlmeyer
- Evelyn Wenkel
- Michael Uder
- Dominika Skwierawska
- Katharina Tkotz
- Dominique Hadler
- Tristan A Kuder
- Frederik B Laun
Abstract
Background: Selecting appropriate sample sizes in magnetic resonance imaging studies is a complex process that requires to balance statistical rigor with the practical challenges of measuring a large patient population. In this Institutional Review Board approved study, we evaluate the dominant error types (“finite N” errors versus precision errors) for apparent diffusion coefficient (ADC)-based lesion characterization in diffusion-weighted magnetic resonance imaging (DWI) of the female breast in a local dataset and compare our results with current literature. Methods: First, in a literature review including 24 published breast DWI studies, the standard error of the area under the receiver operating characteristic curve as a measure of sample size-related errors (finite N errors) was estimated for the reported ADC values and compared to the values, derived from expert readings of a university hospital’s cohort of 171 patients with suspicious breast lesions. Second, precision errors were assessed based on published analyses of the coefficient of variation of ADC values, measured in breast DWI exams. Results: Finite N errors were dominant in the in-house study and most of the 24 reviewed studies. The median sample size at which finite N errors and precision errors were equal was determined to be n = 932. Discussion: This analysis of dominant error types shows that the required sample sizes for the considered use case are not unreasonably large and that reducing sample sizes may not be justified based on the merits of the conducted analysis. Nonetheless, incorporating dominant error type assessments into future studies may provide valuable insights for optimizing study design and improving methodological rigor.
Suggested Citation
Jessica V Eberle & Sebastian Bickelhaupt & Lorenz A Kapsner & Sabine Ohlmeyer & Evelyn Wenkel & Michael Uder & Dominika Skwierawska & Katharina Tkotz & Dominique Hadler & Tristan A Kuder & Frederik B , 2026.
"Finite sample size errors in the context of multiple error sources in quantitative medical imaging: An evaluation for breast magnetic resonance diffusion-weighted imaging,"
PLOS ONE, Public Library of Science, vol. 21(6), pages 1-24, June.
Handle:
RePEc:plo:pone00:0341201
DOI: 10.1371/journal.pone.0341201
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0341201. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.