IDEAS home Printed from https://ideas.repec.org/a/plo/pone00/0339841.html

Monte Carlo dosimetric characterization of the IRAsource high dose rate Iridium-192 brachytherapy source: Comparison with the mHDR-v2r model

Author

Listed:
  • Shuhei Tsuji

Abstract

The aim of this study was to evaluate the dosimetric characteristics of an IRAsource brachytherapy source using Monte Carlo simulations incorporating source electron effects. The dose rate constant, radial dose function, and two-dimensional (2D) anisotropy function were calculated and compared with those of published data and results of the mHDR-v2r source model. The dose rate constant obtained for the IRAsource was (1.1142±0.0030) cGyh−1U−1, which was consistent with previously reported values, within the range of experimental uncertainty. The radial dose function exhibited a pattern similar to that of the mHDR-v2r source, with dose distributions converging at distances of approximately 10 cm, where the effect of capsule thickness became negligible. The 2D anisotropy function did not fully align with other experimental datasets for the IRAsource. Even when comparing the IRAsource with mHDR-v2r sources, the 2D anithotropy function showed a difference of 3% to 6% around 0 degrees at distances of 0.25 cm to 5.0 cm from the source. The results reflected reasonable trends that were consistent with differences in source capsule geometry of the IRAsource and the mHDR-v2r. These findings show that the dosimetric data presented here is reliable. This study provides essential baseline data for accurate dose assessment of the IRAsource in brachytherapy and underscores the importance of further experimental validation to refine dose characterization.

Suggested Citation

  • Shuhei Tsuji, 2026. "Monte Carlo dosimetric characterization of the IRAsource high dose rate Iridium-192 brachytherapy source: Comparison with the mHDR-v2r model," PLOS ONE, Public Library of Science, vol. 21(2), pages 1-13, February.
  • Handle: RePEc:plo:pone00:0339841
    DOI: 10.1371/journal.pone.0339841
    as

    Download full text from publisher

    File URL: https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0339841
    Download Restriction: no

    File URL: https://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0339841&type=printable
    Download Restriction: no

    File URL: https://libkey.io/10.1371/journal.pone.0339841?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    References listed on IDEAS

    as
    1. Shuhei Tsuji & Naomasa Narihiro & Masataka Oita & Yoshihito Namito & Hideo Hirayama, 2024. "High dose rate 192Ir brachytherapy source model Monte Carlo dosimetry: mHDR-v2 and mHDR-v2r," PLOS ONE, Public Library of Science, vol. 19(2), pages 1-17, February.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.

      More about this item

      Statistics

      Access and download statistics

      Corrections

      All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0339841. See general information about how to correct material in RePEc.

      If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

      If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

      If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

      For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .

      Please note that corrections may take a couple of weeks to filter through the various RePEc services.

      IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.