Author
Listed:
- Wenchao Bao
- Quan An
- Hao Zhai
- Shubo Wang
- Renkai Bao
Abstract
Broadband seismometers, distinguished by their large dynamic range and wide bandwidth, have seen increasingly widespread application in earthquake early warning systems and seismological research in recent years. A quantitative investigation into the discrepancies in background noise Power Spectral Density (PSD) recorded by co-located broadband seismometers, operating with and without protective enclosures, is of substantial importance for enhancing the data quality and improving the utilization efficiency of these instruments. This paper utilizes co-located observational data from seismographic instruments (equipped with enclosures) and early warning sensors (without enclosures), installed at earthquake early warning reference stations in the Inner Mongolia region, to quantitatively investigate the noise reduction characteristics of seismometer enclosures across various frequency points, under different spatio-temporal conditions, for different components, and in diverse observational settings. The results demonstrate that subsequent to the installation of seismometer enclosures: Within the low-frequency band of 0.02–0.05 Hz, the enclosures effectively mitigate temperature fluctuations and airflow disturbances, thereby suppressing background noise. The efficacy of this suppression exhibits dependencies on both component orientation and frequency; specifically, the suppression of horizontal noise components exceeds that of the vertical component, with this noise-reducing effect becoming increasingly prominent at longer periods. The mean difference for the East-West component is 3.5 dB (median: 1 dB), while the mean difference for the vertical component is 2.2 dB. This characteristic is consistently corroborated by amplitude-squared coherence analyses performed on teleseismic event data (with the difference between the two components being approximately 0.2). Furthermore, surface-based installations benefit more significantly from such noise reduction than those situated in vaults or caves, a difference potentially attributable to the inherently greater thermal stability of subterranean environments. In the primary microseism band (0.05–0.1 Hz), the enclosures provide a discernible noise reduction effect, suggesting that the sources of primary microseisms are not solely oceanic in origin but are also modulated to some extent by the local environment proximal to the seismometer. Conversely, in the secondary microseism band (0.1–0.5 Hz) and the high-frequency band (0.5–40 Hz), the enclosures offer essentially no discernible noise reduction.
Suggested Citation
Wenchao Bao & Quan An & Hao Zhai & Shubo Wang & Renkai Bao, 2025.
"Noise reduction characteristics of broadband seismometer enclosures,"
PLOS ONE, Public Library of Science, vol. 20(12), pages 1-14, December.
Handle:
RePEc:plo:pone00:0339303
DOI: 10.1371/journal.pone.0339303
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0339303. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.