Abstract
Mortise-tenon and joint-flange assembled foundation has excellent application as a new type of slab concrete assembled foundation, but there is a lack of research on its bearing capacity. In order to explore the mechanical characteristics and bearing capacity of this type of foundation under combined load (uplift-horizontal load), which is different from the traditional cast-in-place foundation, the uplift bearing model of mortise-tenon and joint-flange assembled foundation and the uplift model of cast-in-place foundation with the same specification were established based on the actual geological environment by finite element software. The stress distribution, vertical and horizontal displacements, and uplift and horizontal bearing capacities of the foundations were simulated and calculated. This study found that the bearing capacity of the Mortise-tenon and joint-flange assembled foundation has not been fully utilized. Specifically, the deformation of the foundation mainly concentrates on the main column, and the load is unable to be transmitted to the lower structure through the flange. Under combined loading (uplift-horizontal load), the load-displacement relationship curve can be roughly divided into three stages: linear slow rise stage, plastic accelerated rise stage, and linear failure stage. During the pull-out process, the foundation demonstrates stress characteristics of segmented load transmission. After the concrete upper column yields, the mortise-tenon and joint-flange connection node receives the load transmitted by the upper column, and continues to transmit the load to the lower column of the foundation after the displacement of the node reaches its limit. When the uplift cumulative displacement of the foundation reaches approximately 13 mm and the horizontal cumulative displacement reaches around 10 mm, the foundation reaches its ultimate state. At this point, its ultimate bearing capacity surpasses that of the cast-in-place foundation of the same specification, with significant improvement. The ultimate uplift bearing capacity increases by 33.34%, while the ultimate horizontal bearing capacity increases by 48.09%.
Suggested Citation
Xin Hu & Xiaojuan Xi & Yuesong Zheng & Zijun Xiang & Han Zhang, 2025.
"Study on bearing capacity of Mortise-tenon and joint-flange concrete assembled foundation of transmission line under combined load,"
PLOS ONE, Public Library of Science, vol. 20(8), pages 1-24, August.
Handle:
RePEc:plo:pone00:0327965
DOI: 10.1371/journal.pone.0327965
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0327965. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.