IDEAS home Printed from https://ideas.repec.org/a/plo/pone00/0327733.html
   My bibliography  Save this article

Finger drawing on smartphone screens enables early Parkinson’s disease detection through hybrid 1D-CNN and BiGRU deep learning architecture

Author

Listed:
  • Zhaohui Zhu
  • E Wu
  • Pengfei Leng
  • Jiajun Sun
  • Mingming Ma
  • Zhigeng Pan

Abstract

Background: Parkinson’s disease (PD), a progressive neurodegenerative disorder prevalent in aging populations, manifests clinically through characteristic motor impairments including bradykinesia, rigidity, and resting tremor. Early detection and timely intervention may delay disease progression. Spiral drawing tasks have been established as effective auxiliary diagnostic tools. This study developed a hybrid deep learning model to analyze motion data from finger drawings of spiral and wave lines on smartphone screens, aiming to detect early Parkinson’s disease. Methods: We recruited 58 age-matched participants (28 early idiopathic PD patients: 68.4 ± 5.7 years; 30 healthy controls: 68.0 ± 4.5 years) for two smartphone-based drawing tasks (spiral and wave). A custom-developed app recorded finger touch coordinates, instantaneous movement speed, and timestamps at a sampling frequency of 60 Hz. Our hybrid model combined multi-scale convolutional feature extraction (using parallel 1D-Convolutional branches) with bidirectional temporal pattern recognition (via gated recurrent unit [GRU] networks) to analyze movement abnormalities and detect the disease. Results: The proposed model demonstrated robust diagnostic performance, achieving a cross-validation accuracy of 87.93% for spiral drawings (89.64% sensitivity, 86.33% specificity). Wave drawings yielded 87.24% accuracy (86.79% sensitivity, 87.67% specificity). The integration of both tasks achieved 91.20% accuracy (95% CI: 89.2%−93.2%) with balanced sensitivity (91.43%) and specificity (91.00%). Conclusion: This study establishes the technical feasibility of a hybrid deep learning framework for early PD detection using smartphone-captured finger motion dynamics. The developed model effectively combines one-dimensional convolutional neural networks with bidirectional GRUs to analyze drawing tasks. Distinct from existing approaches that rely on clinical rating scales, neuroimaging modalities, or stylus-based digital assessments, this telemedicine-compatible method requires only bare-finger interactions on consumer-grade smartphones and enables operator-independent assessments. Furthermore, it facilitates cost-effective and convenient PD assessment in remote healthcare and patient monitoring, particularly in resource-limited settings.

Suggested Citation

  • Zhaohui Zhu & E Wu & Pengfei Leng & Jiajun Sun & Mingming Ma & Zhigeng Pan, 2025. "Finger drawing on smartphone screens enables early Parkinson’s disease detection through hybrid 1D-CNN and BiGRU deep learning architecture," PLOS ONE, Public Library of Science, vol. 20(7), pages 1-19, July.
  • Handle: RePEc:plo:pone00:0327733
    DOI: 10.1371/journal.pone.0327733
    as

    Download full text from publisher

    File URL: https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0327733
    Download Restriction: no

    File URL: https://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0327733&type=printable
    Download Restriction: no

    File URL: https://libkey.io/10.1371/journal.pone.0327733?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    More about this item

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0327733. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.