Author
Listed:
- Lin Wang
- Hui Wang
- Yuxi Wang
- Yuwen Wang
- Yuxiu Liu
Abstract
Background: The effect of different concentrations of heparin-locking solution for central venous catheters (CVC) in hemodialysis patients is varied. Regarding the optimal concentration of heparin-locking solution, there is no definitive consensus based on evidence. Objective: To investigate the efficacy and safety of different concentrations of heparin for CVC locking in hemodialysis patients. Methods: We searched PubMed, Embase, Web of science, the Cochrane Library and Clinical Trial Database (clinicaltrials.gov) from establishment of each database to September 19, 2024 for randomized control trials (RCTs), non-randomized control trials (NRCTs) and cohort study of heparin-locking solution for CVC in hemodialysis patients aged ≥ 18 years. Outcome data regarding catheter occlusion, hemodialysis blood flow, bleeding-related complications, catheter-related infection, and catheter retention time were extracted and pooled from selected studies. The quality of included RCTS, cohort studies, and NRCT were assessed using bias risk tools recommended in the Cochrane Handbook. A fixed-effect model was used to calculate pooled odds ratios or mean differences with 95% confidence intervals. Results: Three RCTs, three cohort studies and one NRCT involving 946 hemodialysis patients were included. Heparin-locking solution of 1000 U/ml reduces the occurrence of bleeding related complications (OR = 0.20, 95%CI: 0.05-0.79, P = 0.02) compared to 5000 U/ml and 10000 U/ml. No significant difference was observed in hemodialysis blood flow (MD = -6.95, 95% CI: -14.41- 0.51, P = 0.07), catheter occlusion (OR = 0.89, 95% CI = 0.60-1.33, P = 0.58), catheter retention time (MD = -0.16, 95% CI: -1.98 – 1.67, P = 0.87), and catheter-related infection (OR = 0.60, 95%CI: 0.31-1.19, P = 0.14). Conclusion: Our findings suggest that a heparin-locking solution at a concentration of 1000 U/ml for central venous catheters (CVC) in hemodialysis patients may reduce the incidence of bleeding-related complications, without impacting the rates of catheter occlusion, hemodialysis blood flow, catheter retention time, or catheter-related infections. However, due to the limited number of included studies, high-quality randomized controlled trials and cohort studies with long-term follow-up are warranted to further validate these results.
Suggested Citation
Lin Wang & Hui Wang & Yuxi Wang & Yuwen Wang & Yuxiu Liu, 2025.
"Effect of different concentrations of heparin-locking solution for central venous catheters in hemodialysis patients: A systematic review and meta-analysis,"
PLOS ONE, Public Library of Science, vol. 20(3), pages 1-12, March.
Handle:
RePEc:plo:pone00:0320207
DOI: 10.1371/journal.pone.0320207
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0320207. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.