Author
Listed:
- Summer R Jasinski
- Shon Rowan
- David M Presby
- Elizabeth A Claydon
- Emily R Capodilupo
Abstract
Despite considerable health consequences from preterm births, their incidence remains unchanged over recent decades, due partially to limited screening methods and limited use of extant methods. Wearable technology offers a novel, noninvasive, and acceptable way to track vital signs, such as maternal heart rate variability (mHRV). Previous research observed that mHRV declines throughout the first 33 weeks of gestation in term, singleton pregnancies, after which it improves. The aim of this study was to explore whether mHRV inflection is a feature of gestational age or an indication of time to delivery. This retrospective case-control study considered term and preterm deliveries. Remote data collection via non-invasive wearable technology enabled diverse participation with subjects representing 42 US states and 16 countries. Participants (N = 241) were retroactively identified from the WHOOP (Whoop, Inc.) userbase and wore WHOOP straps during singleton pregnancies between March 2021 and October 2022. Mixed effect spline models by gestational age and time until birth were fit for within-person mHRV, grouped into preterm and term births. For term pregnancies, gestational age (Akaike information criterion (AIC) = 26627.6, R2m = 0.0109, R2c = 0.8571) and weeks until birth (AIC = 26616.3, R2m = 0.0112, R2c = 0.8576) were representative of mHRV trends, with significantly stronger fit for weeks until birth (relative log-likelihood ratio = 279.5). For preterm pregnancies, gestational age (AIC = 1861.9, R2m = 0.0016, R2c = 0.8582) and time until birth (AIC = 1848.0, R2m = 0.0100, R2c = 0.8676) were representative of mHRV trends, with significantly stronger fit for weeks until birth (relative log-likelihood ratio = 859.4). This study suggests that wearable technology, such as the WHOOP strap, may provide a digital biomarker for preterm delivery by screening for changes in nighttime mHRV throughout pregnancy that could in turn alert to the need for further evaluation and intervention.
Suggested Citation
Summer R Jasinski & Shon Rowan & David M Presby & Elizabeth A Claydon & Emily R Capodilupo, 2024.
"Wearable-derived maternal heart rate variability as a novel digital biomarker of preterm birth,"
PLOS ONE, Public Library of Science, vol. 19(1), pages 1-9, January.
Handle:
RePEc:plo:pone00:0295899
DOI: 10.1371/journal.pone.0295899
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0295899. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.