The behavior of a sheet pile wall constructed on saturated sand soil and exposed to a distant surcharge load with a finite length at the top of the backfill soil is examined in this study. For this aim, various internal friction angles (φ), and natural ground surface for the groundwater level are considered. Furthermore, it is considered that the sheet pile wall acts as cantilevered and supports a six-meter-high (H) excavation. The simple “45° distribution” (AP) and uniform distribution of “Beton Kalender distribution” (BK) methods are examined with Coulomb’s and Rankine’s earth pressure theories in analytical solutions, while the finite element method (FEM) is used as a numerical method. The present research has two primary goals: a) determining the best analytical approach that provides the maximum bending moment (Mmax) values that are more comparable to those of the FEM b) examining the behavior of the sheet pile wall considering several effects of load scenarios, depth (D) and section type (ST) of the wall, and the soil properties together. In this context, parametrical analyses are performed. Consequently, it is found that the distance of the surcharge load (x1) has a pronounced effect than the intensity (q) and length (Ls) of the surcharge load on the behavior of the sheet pile, and this effect vanishes for the large values of x1. Furthermore, Coulomb theory provides more convenient values with FEM for Mmax than those obtained from Rankine theory. The Mmax values obtained from FEM are generally less than those from BK, while they are greater than those from APC.
Suggested Citation
Recep Akan, 2023.
"The influence of distant surcharge load with a finite length on the cantilever walls,"
PLOS ONE, Public Library of Science, vol. 18(12), pages 1-20, December.
Handle:
RePEc:plo:pone00:0295442
DOI: 10.1371/journal.pone.0295442
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0295442. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.