IDEAS home Printed from https://ideas.repec.org/a/plo/pone00/0291831.html
   My bibliography  Save this article

Optimizing digital implant impressions: Evaluating the significance of scan body image deficiency and alignment under varied scan body exposures

Author

Listed:
  • Pobploy Petchmedyai
  • Prakan Thanasrisuebwong

Abstract

In implant dentistry, the advent of intraoral scanning technology has revolutionized traditional clinical processes by streamlining procedures and ensuring predictable treatment outcomes. However, achieving accurate virtual implant positions using intraoral scanners and scan bodies can be influenced by various clinical and laboratory factors. This study aims to investigate the impact of scan body image capture deficiency and scan body alignment methods in computer-aided design (CAD) software on the accuracy of virtual implant positions, particularly in different implant depths. Three stereolithographic half-arch implant models with different implant depths were prepared, representing three scenarios of scan body exposure: full exposed scan body, 2/3 exposed scan body, and 1/3 exposed scan body. The scan body image capture deficiency and alignment methods were simulated using CAD software. The deviation of virtual implant positions obtained from different scenarios were evaluated using 3D analysis software. The highest angular and linear deviation (0.237±0.059 degrees, 0.084±0.068 mm) were found in the 1/4 upper and lower part scan body deficiency using the 1-point alignment method in the 1/3 exposed scan body. Two-way ANOVA analysis revealed significant effects of scan deficiency on virtual implant position deviations across all scan body exposures, except for the linear deviation when the scan body was exposed 2/3 of its length. Furthermore, scan deficiencies in the 1/4 upper and lower parts of the scan body significantly affected implant angular deviation regardless of scan body exposure, while implant linear deviation was specifically affected when the scan body was exposed to only 1/3 of its total length. Deficiencies in scan body acquisition, particularly in deep soft tissue situations, can lead to deviations in both angular and linear positioning of virtual implants. Employing appropriate scan body alignment methods such as a 3-point alignment approach demonstrates better accuracy compared to a 1-point alignment.

Suggested Citation

  • Pobploy Petchmedyai & Prakan Thanasrisuebwong, 2023. "Optimizing digital implant impressions: Evaluating the significance of scan body image deficiency and alignment under varied scan body exposures," PLOS ONE, Public Library of Science, vol. 18(9), pages 1-14, September.
  • Handle: RePEc:plo:pone00:0291831
    DOI: 10.1371/journal.pone.0291831
    as

    Download full text from publisher

    File URL: https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0291831
    Download Restriction: no

    File URL: https://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0291831&type=printable
    Download Restriction: no

    File URL: https://libkey.io/10.1371/journal.pone.0291831?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    More about this item

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0291831. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.