Abstract
This study aimed to explore the effect of carbon fiber couch on radiotherapy dose attenuation and gamma pass rate in intensity-modulated radiotherapy (IMRT) plans. A phantom inserted with an ionization chamber was placed at different positions of the couch, and the dose was measured by the chamber. Under the same positioning, the phantom dose was calculated using the real and virtual couch images, and the difference in the planned dose of radiotherapy was compared. Ten clinical IMRT plans were selected as dose verification data, and the gamma pass rates were compared between couch addition and non-addition conditions. When the radiation field was near 110° and 250°, the measured value attenuation coefficient of the ionization chamber at the joint of the couch was up to 34%; the attenuation coefficient of the treatment couch from the actual couch image calculated using the treatment planning system (TPS) was up to 33%; the attenuation coefficient of the virtual couch calculated using the TPS was up to 4.0%. The gamma pass rate of the dose verification near gantry angles 110° and 250° was low, and that of the joint could be lower than 85% under the condition of 3%/3 mm. The gamma pass rates of the radiation field passing through the couch were all affected. The dose was affected by the radiation field passing through the couch, with the largest effect when passing through the joint part of the treatment couch, followed by that of the main couch plate and extension plate. When the irradiation field passed through the joint and near 110° and 250° of the main couch, the dose difference was large, making it unsuitable for treatment.
Suggested Citation
Fantu Kong & Meiting Lu & Jie Dong & Donghui Wang & Junyue Shi & Zhenghuan Li, 2022.
"Effect of linear accelerator carbon fiber couch on radiotherapy dose,"
PLOS ONE, Public Library of Science, vol. 17(11), pages 1-12, November.
Handle:
RePEc:plo:pone00:0277332
DOI: 10.1371/journal.pone.0277332
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0277332. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.