Author
Listed:
- Ikenna Enebuse
- Babul K S M Kader Ibrahim
- Mathias Foo
- Ranveer S Matharu
- Hafiz Ahmed
Abstract
Hand-eye calibration is an important step in controlling a vision-guided robot in applications like part assembly, bin picking and inspection operations etc. Many methods for estimating hand-eye transformations have been proposed in literature with varying degrees of complexity and accuracy. However, the success of a vision-guided application is highly impacted by the accuracy the hand-eye calibration of the vision system with the robot. The level of this accuracy depends on several factors such as rotation and translation noise, rotation and translation motion range that must be considered during calibration. Previous studies and benchmarking of the proposed algorithms have largely been focused on the combined effect of rotation and translation noise. This study provides insight on the impact of rotation and translation noise acting in isolation on the hand-eye calibration accuracy. This deviates from the most common method of assessing hand-eye calibration accuracy based on pose noise (combined rotation and translation noise). We also evaluated the impact of the robot motion range used during the hand-eye calibration operation which is rarely considered. We provide quantitative evaluation of our study using six commonly used algorithms from an implementation perspective. We comparatively analyse the performance of these algorithms through simulation case studies and experimental validation using the Universal Robot’s UR5e physical robots. Our results show that these different algorithms perform differently when the noise conditions vary rather than following a general trend. For example, the simultaneous methods are more resistant to rotation noise, whereas the separate methods are better at dealing with translation noise. Additionally, while increasing the robot rotation motion span during calibration enhances the accuracy of the separate methods, it has a negative effect on the simultaneous methods. Conversely, increasing the translation motion range improves the accuracy of simultaneous methods but degrades the accuracy of the separate methods. These findings suggest that those conditions should be considered when benchmarking algorithms or performing a calibration process for enhanced accuracy.
Suggested Citation
Ikenna Enebuse & Babul K S M Kader Ibrahim & Mathias Foo & Ranveer S Matharu & Hafiz Ahmed, 2022.
"Accuracy evaluation of hand-eye calibration techniques for vision-guided robots,"
PLOS ONE, Public Library of Science, vol. 17(10), pages 1-26, October.
Handle:
RePEc:plo:pone00:0273261
DOI: 10.1371/journal.pone.0273261
Download full text from publisher
References listed on IDEAS
- Shaoyan Gai & Feipeng Da & Xu Fang, 2016.
"A Novel Camera Calibration Method Based on Polar Coordinate,"
PLOS ONE, Public Library of Science, vol. 11(10), pages 1-18, October.
- Syed Riaz un Nabi Jafri & Sheraz Shamim & Sadia Muniza Faraz & Asif Ahmed & Syed Muhammad Yasir & Jamshed Iqbal, 2022.
"Characterization and calibration of multiple 2D laser scanners,"
PLOS ONE, Public Library of Science, vol. 17(7), pages 1-28, July.
Full references (including those not matched with items on IDEAS)
Most related items
These are the items that most often cite the same works as this one and are cited by the same works as this one.
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0273261. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.