Author
Listed:
- Nicolaus Dahlmann
- Vera Demond
Abstract
Background: The present study refers to an anthropometric model, Dahlmann-Body-Analysis (DBA), based on formerly developed weight-height-frame tables. Including the anthropometric variable abdomen circumference (AC), a further differentiation into muscularity and fat mass could be realized. This enables to calculate the individual percentage fat mass (%FM), providing a cost-effective method for epidemiological studies. The present work sets out to investigate, whether %FM computed by the DBA model compares to BIA measurements, notably under conditions of heavy obesity. Subjects/methods: In 103 adults (37 males, 66 females, age 42.5 ± 12.5 years, BMI 38.2 ± 4.8 kg/m²) %FM was estimated by a tetrapolar BIA device and compared to results derived by the DBA system. Bland-Altman and simple linear regression analyses were used to determine agreement between methods. Results: The mean %FM estimates of men (women) ± standard deviation were 36.1 ± 4.8 (49.7 ± 4.5) for BIA and 36.7 ± 4.2 (49.1 ± 4.9) for DBA measurements. Pearson correlation coefficients (r) and Lin’s concordance correlation coefficient (CCC) were r = 0.86 and CCC = 0.84 for men and r = 0.85 and CCC = 0.83 for women, respectively. Bland-Altman plot showed limits of agreement between DBA and BIA %FM that ranged from 5.5% to -4.3% for men and 4.6% to– 5.7% for women, respectively. Correlations between values measured by both methods were high and the observed confidence interval (SD of the difference between DBA and BIA result multiplied by 2) was low. No systematic error was found. The DBA system overestimates FM by 0.63 ± 4.98 (2SD) % for men and underestimates FM by -0.56 ± 5.28 (2SD) % for women, respectively, compared to the BIA results. The result for both genders is -0.066 ± 5.17 (2SD) %FM. Over all, there is a strong concordance and reproducibility between the DBA and BIA data sets. Conclusions: The implementation of the abdomen circumference (AC) into the DBA model as a proxy for body fat (%FM) resulted in a strong concordance with BIA measurements. These findings indicate that the DBA model may reflect the body shape of severely obese white European patients with regard to body composition.
Suggested Citation
Nicolaus Dahlmann & Vera Demond, 2022.
"A new anthropometric model for body composition estimation: Comparison with a bioelectrical impedance consumer device,"
PLOS ONE, Public Library of Science, vol. 17(9), pages 1-10, September.
Handle:
RePEc:plo:pone00:0271880
DOI: 10.1371/journal.pone.0271880
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0271880. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.