IDEAS home Printed from https://ideas.repec.org/a/plo/pone00/0253947.html
   My bibliography  Save this article

Shifting from postauricular to transcanal microscopic tympanoplasty may have similar frequency-specific improvements with better air-bone-gap closure at low frequencies and a minimal learning-curve effect

Author

Listed:
  • Ethan I Huang
  • Yu-Chieh Wu
  • Hsiu-Mei Chuang
  • Tzu-Chi Huang

Abstract

The shift from postauricular to transcanal microscopic tympanoplasty brings potential advantages of minimal morbidity, less postoperative pain, patient comfort, and surgical ease and speed, but also uncertainties of unfamiliar grafting material, an inadequate operation view, and an uncertain learning curve. These challenges might affect the successful repair rate and the frequency-specific hearing outcome, which is important for hearing perception. Rare studies reported frequency-specific hearing outcome with the learning curve for shifting from postauricular to transcanal microscopic tympanoplasty. Here, from Jul. 2013 to Nov. 2018, we compared patients in a shift from postauricular approach (35 ears) to transcanal approach (35 ears) of microscopic type-1 tympanoplasty. The results show that both of postauricular and transcanal microscopic tympanoplasties reduced the mean air-bone gap, 0.5k Hz gap, and 1k Hz gap after the surgery. The further analyses on gap change as a function of frequency (0.5, 1, 2, and 4k Hz) show that both of postauricular and transcanal tympanoplasties improved postoperative air-bone gap among the levels of frequency. The post hoc comparisons display a common gap reduction difference between 0.5k and 4k Hz. The successful repair rate did not differ between the 2 groups. There was no correlation between the postoperative mean gap change and the surgery date, suggesting a minimal learning-curve effect. The results of similar frequency-specific improvements and a minimal learning-curve effect may help to ease the concerns of those uncertainties before the shift.

Suggested Citation

  • Ethan I Huang & Yu-Chieh Wu & Hsiu-Mei Chuang & Tzu-Chi Huang, 2021. "Shifting from postauricular to transcanal microscopic tympanoplasty may have similar frequency-specific improvements with better air-bone-gap closure at low frequencies and a minimal learning-curve ef," PLOS ONE, Public Library of Science, vol. 16(7), pages 1-12, July.
  • Handle: RePEc:plo:pone00:0253947
    DOI: 10.1371/journal.pone.0253947
    as

    Download full text from publisher

    File URL: https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0253947
    Download Restriction: no

    File URL: https://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0253947&type=printable
    Download Restriction: no

    File URL: https://libkey.io/10.1371/journal.pone.0253947?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    References listed on IDEAS

    as
    1. Ethan I Huang & Yu-Chieh Wu & Hsiu-Mei Chuang & Tzu-Chi Huang, 2021. "Bone-conduction threshold and air-bone gap may predict frequency-specific air-conduction threshold after tympanoplasty," PLOS ONE, Public Library of Science, vol. 16(3), pages 1-13, March.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.

      More about this item

      Statistics

      Access and download statistics

      Corrections

      All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0253947. See general information about how to correct material in RePEc.

      If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

      If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

      If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

      For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .

      Please note that corrections may take a couple of weeks to filter through the various RePEc services.

      IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.