Author
Listed:
- Shunli Zhang
- Fei Cheng
- Hua Wang
- Jiangping Wen
- Jie Zeng
- Chuanbao Zhang
- Wensong Liu
- Ning Wang
- Tingting Jia
- Mo Wang
- Rui Zhang
- Yuhong Yue
- Jing Xu
- Zhanyong Wang
- Yilong Li
- Wenxiang Chen
- Qingtao Wang
Abstract
Background: This study aimed to assess the comparability among assays using freshly frozen human sera and external quality assessment (EQA) data in China. Methods: Twenty-nine serum samples and two commercial EQA materials, obtained from the National Center for Clinical Laboratories (NCCL), were analyzed in triplicate using eight routine TSH assays. The commutability of commercial EQA materials (NCCL materials) was evaluated in accordance with the CLSI EP30-A and IFCC bias analysis. Median values obtained for the NCCL EQA materials were used to determine the systematic and commutability-related biases among immunoassays through back-calculation. The comparability of TSH measurements from a panel of clinical samples and NCCL EQA data was determined on the basis of Passing–Bablok regression. Furthermore, human serum pools were used to perform commutable EQA. Results: NCCL EQA materials displayed commutability among three or five of seven assay combinations according CLSI or IFCC approach, respectively. The mean of systematic bias ranged from -13.78% to 9.85% for the eight routine TSH assays. After correcting for systematic bias, averaged commutability-related biases ranged between -42.26% and 12.19%. After correction for systematic and commutability -related biases, the slopes indicating interassay relatedness ranged from 0.801 to 1.299 using individual human sera, from 0.735 to 1.254 using NCCL EQA data, and from 0.729 to 1.115 using pooled human serum EQA(the commutable EQA). Conclusions: The harmonization of TSH measurement is challenging; hence, systematic and commutability-related biases should be determined and corrected for accurate comparisons among assays when using human individual serum and the commercial EQA materials.
Suggested Citation
Shunli Zhang & Fei Cheng & Hua Wang & Jiangping Wen & Jie Zeng & Chuanbao Zhang & Wensong Liu & Ning Wang & Tingting Jia & Mo Wang & Rui Zhang & Yuhong Yue & Jing Xu & Zhanyong Wang & Yilong Li & Wenx, 2021.
"Comparability of thyroid-stimulating hormone immunoassays using fresh frozen human sera and external quality assessment data,"
PLOS ONE, Public Library of Science, vol. 16(6), pages 1-13, June.
Handle:
RePEc:plo:pone00:0253324
DOI: 10.1371/journal.pone.0253324
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0253324. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .
Please note that corrections may take a couple of weeks to filter through