Can we use rapid lifetime determination for fast, fluorescence lifetime based, metabolic imaging? Precision and accuracy of double-exponential decay measurements with low total counts

Author

Listed:
  • Susana Figueiredo Silva
  • José Paulo Domingues
  • António Miguel Morgado

Abstract

Fluorescence lifetime imaging microscopy (FLIM) can assess cell’s metabolism through the fluorescence of the co-enzymes NADH and FAD, which exhibit a double-exponential decay, with components related to free and protein-bound conditions. In vivo real time clinical imaging applications demand fast acquisition. As photodamage limits excitation power, this is best achieved using wide-field techniques, like time-gated FLIM, and algorithms that require few images to calculate the decay parameters. The rapid lifetime determination (RLD) algorithm requires only four images to analyze a double-exponential decay. Using computational simulations, we evaluated the accuracy and precision of RLD when measuring endogenous fluorescence lifetimes and metabolic free to protein-bound ratios, for total counts per pixel (TC) lower than 104. The simulations were based on a time-gated FLIM instrument, accounting for its instrument response function, gain and noise. While the optimal acquisition setting depends on the values being measured, the accuracy of the free to protein-bound ratio α2/α1 is stable for low gains and gate separations larger than 1000 ps, while its precision is almost constant for gate separations between 1500 and 2500 ps. For the gate separations and free to protein-bound ratios considered, the accuracy error can be as high as 30% and the precision error can reach 60%. Precision errors lower than 10% cannot be obtained. The best performance occurs for low camera gains and gate separations near 1800 ps. When considering the narrow physiological ranges for the free to protein-bound ratio, the precision errors can be confined to an interval between 10% and 20%. RLD is a valid option when for real time FLIM. The simulations and methodology presented here can be applied to any time-gated FLIM instrument and are useful to obtain the accuracy and precision limits for RLD in the demanding conditions of TC lower than 104.

Suggested Citation

  • Susana Figueiredo Silva & José Paulo Domingues & António Miguel Morgado, 2019. "Can we use rapid lifetime determination for fast, fluorescence lifetime based, metabolic imaging? Precision and accuracy of double-exponential decay measurements with low total counts," PLOS ONE, Public Library of Science, vol. 14(5), pages 1-20, May.
  • Handle: RePEc:plo:pone00:0216894
    DOI: 10.1371/journal.pone.0216894
    as

    Download full text from publisher

    File URL: https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0216894
    Download Restriction: no

    File URL: https://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0216894&type=printable
    Download Restriction: no

    File URL: https://libkey.io/10.1371/journal.pone.0216894?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    More about this item

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0216894. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.