Real time monitoring of transtibial elevated vacuum prostheses: A case series on socket air pressure

Author

Listed:
  • Katherine R Schoepp
  • Jonathon S Schofield
  • David Home
  • Michael R Dawson
  • Edmond Lou
  • McNiel Keri
  • Paul D Marasco
  • Jacqueline S Hebert

Abstract

Prosthetic elevated vacuum is a suspension method used to reduce daily volume changes of the residual limb. Evaluation of the effectiveness of these systems is limited due to a lack of correlation to actual socket air pressure, particularly during unconstrained movements. This may explain some of the variability in functional outcomes reported in the literature. Our objective was to develop a light-weight portable socket measurement system to quantify internal socket air pressure, temperature, and acceleration; and to present preliminary results from implementation with three transtibial prosthesis users with mechanical elevated vacuum pumps. Participants completed five functional tasks with and without the vacuum pumps actively connected, including the 2-Minute Walk test, 5-Times Sit-to-Stand test, 4-Square Step test, L-Test, and Figure-8 test. Results demonstrated different gait profiles and pressure ranges for each user. Two of the participants demonstrated substantially lower air pressure (higher vacuum) over time while the pump was active compared to inactive. The minimum air pressure measured for all participants was -34.6 ± 7.7 kPa. One participant did not show substantial changes in pressure over time for either pump condition. Functional task performance was not significantly different between pump conditions. Correlation with accelerometer readings indicated peak positive pressures occurred just following initial contact of the foot in early stance, and the most negative pressures (highest vacuum) were observed throughout swing. This study has demonstrated the use of a portable data logging tool that may serve the clinical and research communities to quantify the operation of elevated vacuum systems, and better understand the variability of mechanical pump operation and overall system performance.

Suggested Citation

  • Katherine R Schoepp & Jonathon S Schofield & David Home & Michael R Dawson & Edmond Lou & McNiel Keri & Paul D Marasco & Jacqueline S Hebert, 2018. "Real time monitoring of transtibial elevated vacuum prostheses: A case series on socket air pressure," PLOS ONE, Public Library of Science, vol. 13(10), pages 1-15, October.
  • Handle: RePEc:plo:pone00:0202716
    DOI: 10.1371/journal.pone.0202716
    as

    Download full text from publisher

    File URL: https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0202716
    Download Restriction: no

    File URL: https://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0202716&type=printable
    Download Restriction: no

    File URL: https://libkey.io/10.1371/journal.pone.0202716?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    More about this item

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0202716. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.