IDEAS home Printed from https://ideas.repec.org/a/plo/pone00/0075098.html
   My bibliography  Save this article

Feasibility and Reproducibility of Left Ventricular Rotation by Speckle Tracking Echocardiography in Elderly Individuals and the Impact of Different Software

Author

Listed:
  • Chloe M Park
  • Katherine March
  • Suzanne Williams
  • Suraj Kukadia
  • Arjun K Ghosh
  • Siana Jones
  • Therese Tillin
  • Nish Chaturvedi
  • Alun D Hughes

Abstract

Background: Changes in ventricular rotation measured by two-dimensional speckle tracking echocardiography (2DSTE) are early indicators of cardiac disease. Data on the clinical feasibility of this important measure are scarce and there is no information on the comparability of different software versions. We assessed the feasibility, reproducibility and within patient temporal variability of 2DSTE in a large community based sample of older adults. We additionally compared 2DSTE results to those generated by 3DSTE. Methods and results: 1408 participants underwent transthoracic echocardiography. Using Philips Qlab 8.1 peak LV rotation at either the base or the apex was analysable in 432 (31%) participants. Peak twist measurements were achieved in 274 (20%) participants. 66 participants were randomly selected for the reproducibility study. 20 additional participants had scans 4–6 weeks apart for temporal variability and 3D echocardiography to assess the agreement between 2DSTE and 3DSTE. Reproducibility was evaluated using the intraclass coefficient of correlation (ICC). Better reproducibility for rotation and twist were obtained when measured at the endocardium, and when using more recent software versions, Peak twist and rotation were significantly different using two versions of the same software. Agreement with 3DSTE was better using newer software. Conclusion: Feasibility of 2DSTE is low in this cohort of elderly individuals severely limiting its utility in clinical settings. However if high quality images can be acquired assessment of ventricular rotation by 2DSTE is reproducible. Caution should be taken when comparing measurements of ventricular rotation by software from different vendors or different versions of software from the same vendor.

Suggested Citation

  • Chloe M Park & Katherine March & Suzanne Williams & Suraj Kukadia & Arjun K Ghosh & Siana Jones & Therese Tillin & Nish Chaturvedi & Alun D Hughes, 2013. "Feasibility and Reproducibility of Left Ventricular Rotation by Speckle Tracking Echocardiography in Elderly Individuals and the Impact of Different Software," PLOS ONE, Public Library of Science, vol. 8(9), pages 1-9, September.
  • Handle: RePEc:plo:pone00:0075098
    DOI: 10.1371/journal.pone.0075098
    as

    Download full text from publisher

    File URL: https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0075098
    Download Restriction: no

    File URL: https://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0075098&type=printable
    Download Restriction: no

    File URL: https://libkey.io/10.1371/journal.pone.0075098?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    More about this item

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0075098. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.