Author
Abstract
Background: Recently two major manufacturers of hearing aids introduced two distinct frequency-lowering techniques that were designed to compensate in part for the perceptual effects of high-frequency hearing impairments. The Widex “Audibility Extender” is a linear frequency transposition scheme, whereas the Phonak “SoundRecover” scheme employs nonlinear frequency compression. Although these schemes process sound signals in very different ways, studies investigating their use by both adults and children with hearing impairment have reported significant perceptual benefits. However, the modifications that these innovative schemes apply to sound signals have not previously been described or compared in detail. Methods: The main aim of the present study was to analyze these schemes'technical performance by measuring outputs from each type of hearing aid with the frequency-lowering functions enabled and disabled. The input signals included sinusoids, flute sounds, and speech material. Spectral analyses were carried out on the output signals produced by the hearing aids in each condition. Conclusions: The results of the analyses confirmed that each scheme was effective at lowering certain high-frequency acoustic signals, although both techniques also distorted some signals. Most importantly, the application of either frequency-lowering scheme would be expected to improve the audibility of many sounds having salient high-frequency components. Nevertheless, considerably different perceptual effects would be expected from these schemes, even when each hearing aid is fitted in accordance with the same audiometric configuration of hearing impairment. In general, these findings reinforce the need for appropriate selection and fitting of sound-processing schemes in modern hearing aids to suit the characteristics and preferences of individual listeners.
Suggested Citation
Hugh J McDermott, 2011.
"A Technical Comparison of Digital Frequency-Lowering Algorithms Available in Two Current Hearing Aids,"
PLOS ONE, Public Library of Science, vol. 6(7), pages 1-6, July.
Handle:
RePEc:plo:pone00:0022358
DOI: 10.1371/journal.pone.0022358
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0022358. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.