Author
Listed:
- Lara Vojnov
- Sergio Carmona
- Clement Zeh
- Jessica Markby
- Debrah Boeras
- Marta R Prescott
- Anthony L H Mayne
- Souleymane Sawadogo
- Christiane Adje-Toure
- Guoqing Zhang
- Mercedes Perez Gonzalez
- Wendy S Stevens
- Meg Doherty
- Chunfu Yang
- Heather Alexander
- Trevor F Peter
- John Nkengasong
- the DBS for VL Diagnostics Investigation Consortium
Abstract
Background: Accurate routine HIV viral load testing is essential for assessing the efficacy of antiretroviral treatment (ART) regimens and the emergence of drug resistance. While the use of plasma specimens is the standard for viral load testing, its use is restricted by the limited ambient temperature stability of viral load biomarkers in whole blood and plasma during storage and transportation and the limited cold chain available between many health care facilities in resource-limited settings. Alternative specimen types and technologies, such as dried blood spots, may address these issues and increase access to viral load testing; however, their technical performance is unclear. To address this, we conducted a meta-analysis comparing viral load results from paired dried blood spot and plasma specimens analyzed with commonly used viral load testing technologies. Methods and findings: Standard databases, conferences, and gray literature were searched in 2013 and 2018. Nearly all studies identified (60) were conducted between 2007 and 2018. Data from 40 of the 60 studies were included in the meta-analysis, which accounted for a total of 10,871 paired dried blood spot:plasma data points. We used random effects models to determine the bias, accuracy, precision, and misclassification for each viral load technology and to account for between-study variation. Dried blood spot specimens produced consistently higher mean viral loads across all technologies when compared to plasma specimens. However, when used to identify treatment failure, each technology compared best to plasma at a threshold of 1,000 copies/ml, the present World Health Organization recommended treatment failure threshold. Some heterogeneity existed between technologies; however, 5 technologies had a sensitivity greater than 95%. Furthermore, 5 technologies had a specificity greater than 85% yet 2 technologies had a specificity less than 60% using a treatment failure threshold of 1,000 copies/ml. The study’s main limitation was the direct applicability of findings as nearly all studies to date used dried blood spot samples prepared in laboratories using precision pipetting that resulted in consistent input volumes. Conclusions: This analysis provides evidence to support the implementation and scale-up of dried blood spot specimens for viral load testing using the same 1,000 copies/ml treatment failure threshold as used with plasma specimens. This may support improved access to viral load testing in resource-limited settings lacking the required infrastructure and cold chain storage for testing with plasma specimens. Lara Vojnov and co-workers report on the use of dried blood spots for HIV viral load testing.Why was this study done?: What did the researchers do and find?: What do these findings mean?:
Suggested Citation
Lara Vojnov & Sergio Carmona & Clement Zeh & Jessica Markby & Debrah Boeras & Marta R Prescott & Anthony L H Mayne & Souleymane Sawadogo & Christiane Adje-Toure & Guoqing Zhang & Mercedes Perez Gonzal, 2022.
"The performance of using dried blood spot specimens for HIV-1 viral load testing: A systematic review and meta-analysis,"
PLOS Medicine, Public Library of Science, vol. 19(8), pages 1-34, August.
Handle:
RePEc:plo:pmed00:1004076
DOI: 10.1371/journal.pmed.1004076
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pmed00:1004076. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosmedicine (email available below). General contact details of provider: https://journals.plos.org/plosmedicine/ .
Please note that corrections may take a couple of weeks to filter through