IDEAS home Printed from https://ideas.repec.org/a/plo/pmed00/1002428.html
   My bibliography  Save this article

Bioequivalence between innovator and generic tacrolimus in liver and kidney transplant recipients: A randomized, crossover clinical trial

Author

Listed:
  • Rita R Alloway
  • Alexander A Vinks
  • Tsuyoshi Fukuda
  • Tomoyuki Mizuno
  • Eileen C King
  • Yuanshu Zou
  • Wenlei Jiang
  • E Steve Woodle
  • Simon Tremblay
  • Jelena Klawitter
  • Jost Klawitter
  • Uwe Christians

Abstract

Background: Although the generic drug approval process has a long-term successful track record, concerns remain for approval of narrow therapeutic index generic immunosuppressants, such as tacrolimus, in transplant recipients. Several professional transplant societies and publications have generated skepticism of the generic approval process. Three major areas of concern are that the pharmacokinetic properties of generic products and the innovator (that is, “brand”) product in healthy volunteers may not reflect those in transplant recipients, bioequivalence between generic and innovator may not ensure bioequivalence between generics, and high-risk patients may have specific bioequivalence concerns. Such concerns have been fueled by anecdotal observations and retrospective and uncontrolled published studies, while well-designed, controlled prospective studies testing the validity of the regulatory bioequivalence testing approach for narrow therapeutic index immunosuppressants in transplant recipients have been lacking. Thus, the present study prospectively assesses bioequivalence between innovator tacrolimus and 2 generics in individuals with a kidney or liver transplant. Methods and findings: From December 2013 through October 2014, a prospective, replicate dosing, partially blinded, randomized, 3-treatment, 6-period crossover bioequivalence study was conducted at the University of Cincinnati in individuals with a kidney (n = 35) or liver transplant (n = 36). Abbreviated New Drug Applications (ANDA) data that included manufacturing and healthy individual pharmacokinetic data for all generics were evaluated to select the 2 most disparate generics from innovator, and these were named Generic Hi and Generic Lo. During the 8-week study period, pharmacokinetic studies assessed the bioequivalence of Generic Hi and Generic Lo with the Innovator tacrolimus and with each other. Bioequivalence of the major tacrolimus metabolite was also assessed. All products fell within the US Food and Drug Administration (FDA) average bioequivalence (ABE) acceptance criteria of a 90% confidence interval contained within the confidence limits of 80.00% and 125.00%. Within-subject variability was similar for the area under the curve (AUC) (range 12.11–15.81) and the concentration maximum (Cmax) (range 17.96–24.72) for all products. The within-subject variability was utilized to calculate the scaled average bioequivalence (SCABE) 90% confidence interval. The calculated SCABE 90% confidence interval was 84.65%–118.13% and 80.00%–125.00% for AUC and Cmax, respectively. The more stringent SCABE acceptance criteria were met for all product comparisons for AUC and Cmax in both individuals with a kidney transplant and those with a liver transplant. European Medicines Agency (EMA) acceptance criteria for narrow therapeutic index drugs were also met, with the only exception being in the case of Brand versus Generic Lo, in which the upper limits of the 90% confidence intervals were 111.30% (kidney) and 112.12% (liver). These were only slightly above the upper EMA acceptance criteria limit for an AUC of 111.11%. SCABE criteria were also met for the major tacrolimus metabolite 13-O-desmethyl tacrolimus for AUC, but it failed the EMA criterion. No acute rejections, no differences in renal function in all individuals, and no differences in liver function were observed in individuals with a liver transplant using the Tukey honest significant difference (HSD) test for multiple comparisons. Fifty-two percent and 65% of all individuals with a kidney or liver transplant, respectively, reported an adverse event. The Exact McNemar test for paired categorical data with adjustments for multiple comparisons was used to compare adverse event rates among the products. No statistically significant differences among any pairs of products were found for any adverse event code or for adverse events overall. Limitations of this study include that the observations were made under strictly controlled conditions that did not allow for the impact of nonadherence or feeding on the possible pharmacokinetic differences. Generic Hi and Lo were selected based upon bioequivalence data in healthy volunteers because no pharmacokinetic data in recipients were available for all products. The safety data should be interpreted in light of the small number of participants and the short observation periods. Lastly, only the 1 mg tacrolimus strength was utilized in this study. Conclusions: Using an innovative, controlled bioequivalence study design, we observed equivalence between tacrolimus innovator and 2 generic products as well as between 2 generic products in individuals after kidney or liver transplantation following current FDA bioequivalence metrics. These results support the position that bioequivalence for the narrow therapeutic index drug tacrolimus translates from healthy volunteers to individuals receiving a kidney or liver transplant and provides evidence that generic products that are bioequivalent with the innovator product are also bioequivalent to each other. Trial registration: ClinicalTrials.gov NCT01889758. In a randomized 3-treatment crossover clinical trial, Rita Alloway of the University of Cincinnati and colleagues establish bioequivalence between 3 versions of the drug tracolimus (a brand name and 2 disparate generics) in kidney and liver transplant recipients.Why was this study done?: What did the researchers do and find?: What do these findings mean?:

Suggested Citation

  • Rita R Alloway & Alexander A Vinks & Tsuyoshi Fukuda & Tomoyuki Mizuno & Eileen C King & Yuanshu Zou & Wenlei Jiang & E Steve Woodle & Simon Tremblay & Jelena Klawitter & Jost Klawitter & Uwe Christia, 2017. "Bioequivalence between innovator and generic tacrolimus in liver and kidney transplant recipients: A randomized, crossover clinical trial," PLOS Medicine, Public Library of Science, vol. 14(11), pages 1-22, November.
  • Handle: RePEc:plo:pmed00:1002428
    DOI: 10.1371/journal.pmed.1002428
    as

    Download full text from publisher

    File URL: https://journals.plos.org/plosmedicine/article?id=10.1371/journal.pmed.1002428
    Download Restriction: no

    File URL: https://journals.plos.org/plosmedicine/article/file?id=10.1371/journal.pmed.1002428&type=printable
    Download Restriction: no

    File URL: https://libkey.io/10.1371/journal.pmed.1002428?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    More about this item

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pmed00:1002428. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosmedicine (email available below). General contact details of provider: https://journals.plos.org/plosmedicine/ .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.