IDEAS home Printed from https://ideas.repec.org/a/nat/nature/v501y2013i7468d10.1038_nature12590.html
   My bibliography  Save this article

Zhang et al. reply

Author

Listed:
  • X. Z. Zhang

    (Laboratory of Advanced Materials, Tsinghua University
    Beijing National Center for Electron Microscopy, Tsinghua University)

  • C. H. Wan

    (Laboratory of Advanced Materials, Tsinghua University
    Beijing National Center for Electron Microscopy, Tsinghua University)

  • X. L. Gao

    (Laboratory of Advanced Materials, Tsinghua University
    Beijing National Center for Electron Microscopy, Tsinghua University)

  • J. M. Wang

    (Laboratory of Advanced Materials, Tsinghua University
    Beijing National Center for Electron Microscopy, Tsinghua University)

  • X. Y. Tan

    (Laboratory of Advanced Materials, Tsinghua University
    Beijing National Center for Electron Microscopy, Tsinghua University)

Abstract

replying to J. Luo et al. Nature 501, 10.1038/nature12589 (2013). We agree with Luo et al.1 that the magnetoresistance effects that we reported2 were dependent on the method used to measure them. The reason that there is a difference in the results depending on whether method 1 or method 2 is used (adopting the measurement notation of ref. 1) is that there are two voltage-stabilizing diodes in the Keithley 2400 instrument we used. We were unaware that when this instrument was used both as current source and voltmeter, one diode connected the input port of the current source to the input port of the voltmeter, whereas the other diode connected the output port of the current source to the output port of the voltmeter. The diodes caused a crossover of the Hall coefficient from negative to positive when the instrument was used to conduct a Hall measurement in this configuration, leading us to propose an invalid mechanism for the abnormal magnetoresistance. Therefore the mechanism we proposed2—minority injection and an induced p-n boundary—does not provide a correct explanation for the observed geometry-enhanced magnetoresistance. Although such a mechanism does not operate in our samples, we note that a p–n boundary could still enhance magnetoresistance in certain circumstances according to our and others’ theoretical calculations and experiments2,3,4.

Suggested Citation

  • X. Z. Zhang & C. H. Wan & X. L. Gao & J. M. Wang & X. Y. Tan, 2013. "Zhang et al. reply," Nature, Nature, vol. 501(7468), pages 1-2, September.
  • Handle: RePEc:nat:nature:v:501:y:2013:i:7468:d:10.1038_nature12590
    DOI: 10.1038/nature12590
    as

    Download full text from publisher

    File URL: https://www.nature.com/articles/nature12590
    File Function: Abstract
    Download Restriction: Access to the full text of the articles in this series is restricted.

    File URL: https://libkey.io/10.1038/nature12590?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    More about this item

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:nat:nature:v:501:y:2013:i:7468:d:10.1038_nature12590. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Sonal Shukla or Springer Nature Abstracting and Indexing (email available below). General contact details of provider: http://www.nature.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.