Author
Listed:
- Benedikt Krause
(Technical University of Darmstadt, Department of Electrical Engineering and Information Technology)
- Sebastian Müller
(TOPTICA Photonics AG
Friedrich Alexander University, Institute of Microwaves and Photonics)
- Thomas Puppe
(TOPTICA Photonics AG)
- Lars Liebermeister
(Heinrich-Hertz-Institute, Fraunhofer Institute for Telecommunications)
- Garrit Schwanke
(Heinrich-Hertz-Institute, Fraunhofer Institute for Telecommunications)
- Milan Deumer
(Heinrich-Hertz-Institute, Fraunhofer Institute for Telecommunications)
- Robert Kohlhaas
(Heinrich-Hertz-Institute, Fraunhofer Institute for Telecommunications)
- Rafal Wilk
(TOPTICA Photonics AG)
- Nico Vieweg
(TOPTICA Photonics AG)
- Sascha Preu
(Technical University of Darmstadt, Department of Electrical Engineering and Information Technology)
Abstract
Spectrum analyzers and spectrometers are essential for designing sources, analyzing material properties, layer structures and fingerprinting substances. We present an ultra-wideband, continuous-wave photonic receiver with kHz-level spectral resolution in the terahertz domain for both heterodyne and homodyne detection. Employed as a spectrum analyzer front end, it records the emitted spectrum of a source under test, assessing spectral purity, spectral shape and undesired frequency components. It outperforms state-of-the-art electronic systems in terms of frequency coverage and system cost with a competitive spectral resolution and noise floor on the few aW/Hz level at room temperature. It covers the important frequencies above 1.5 THz, yet commercially inaccessible, where sources like quantum cascade lasers operate. When combined with a comb-based photonic source, we demonstrate hetero- and homodyne spectroscopy over an unprecedented frequency range from below 100 GHz to 6.5 THz and a very low noise floor. Locking the photonic system to GPS enables tracing back the measured parameters to SI units, being of key importance for metrological applications. The presented setups offer the broadest continuous-wave frequency coverage to date, combined with a sharp spectral resolution, enabling diverse applications ranging from fast non-destructive testing, astronomic high-resolution spectroscopy, to frequency-modulated RADAR.
Suggested Citation
Benedikt Krause & Sebastian Müller & Thomas Puppe & Lars Liebermeister & Garrit Schwanke & Milan Deumer & Robert Kohlhaas & Rafal Wilk & Nico Vieweg & Sascha Preu, 2025.
"Terahertz photonic heterodyne spectral analysis with (sub-) kHz resolution and 6.5 THz frequency coverage,"
Nature Communications, Nature, vol. 16(1), pages 1-12, December.
Handle:
RePEc:nat:natcom:v:16:y:2025:i:1:d:10.1038_s41467-025-66457-6
DOI: 10.1038/s41467-025-66457-6
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:nat:natcom:v:16:y:2025:i:1:d:10.1038_s41467-025-66457-6. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Sonal Shukla or Springer Nature Abstracting and Indexing (email available below). General contact details of provider: http://www.nature.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.