Author
Listed:
- Sydney E. Sherman
(Harvard-MIT Program in Health Science and Technology, Massachusetts Institute of Technology
Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology)
- Alexa S. Zammit
(Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology
Massachusetts Institute of Technology)
- Won-Seok Heo
(Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology)
- Matthew S. Rosen
(Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital
Harvard Medical School
Harvard University)
- Michael J. Cima
(Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology
Massachusetts Institute of Technology)
Abstract
Magnetic resonance imaging is a widespread clinical tool for the detection of soft tissue morphology and pathology. However, the clinical deployment of magnetic resonance imaging scanners is ultimately limited by size, cost, and space constraints. Here, we discuss the design and performance of a low-field single-sided magnetic resonance sensor intended for point-of-care evaluation of skeletal muscle in vivo. The 11 kg sensor has a penetration depth of >8 mm, which allows for an accurate analysis of muscle tissue and can avoid signal from more proximal layers, including subcutaneous adipose tissue. Low operational power and shielding requirements are achieved through the design of a permanent magnet array and surface transceiver coil. The sensor can acquire high signal-to-noise measurements in minutes, making it practical as a point-of-care tool for many quantitative diagnostic measurements, including T2 relaxometry. In this work, we present the in vitro and human in vivo performance of the device for muscle tissue evaluation.
Suggested Citation
Sydney E. Sherman & Alexa S. Zammit & Won-Seok Heo & Matthew S. Rosen & Michael J. Cima, 2024.
"Single-sided magnetic resonance-based sensor for point-of-care evaluation of muscle,"
Nature Communications, Nature, vol. 15(1), pages 1-9, December.
Handle:
RePEc:nat:natcom:v:15:y:2024:i:1:d:10.1038_s41467-023-44561-9
DOI: 10.1038/s41467-023-44561-9
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:nat:natcom:v:15:y:2024:i:1:d:10.1038_s41467-023-44561-9. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Sonal Shukla or Springer Nature Abstracting and Indexing (email available below). General contact details of provider: http://www.nature.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.