Author
Listed:
- Mohd Atif Hussain
- Rashmi Sakalle
Abstract
In this study, a static linear Eigen value buckling parametric analysis is done for cooling tower shell geometries of 150 m height. The shells are subjected to wind pressures (speeds) of (47 meter per second) and seismic vibrations under zone IV to observe the trends in the critical buckling pressures/speeds at which the shell first buckles and therefore the corresponding buckling modes. The cooling tower’s geometry is changed in a systematic manner along the height to obtain the relationship between applied wind speeds and seismic vibrations associated with the mode of buckling and the cooling tower’s geometry. Geometrical parameter ratios of the cooling tower’s dimensions are considered so as to hide a wider spectrum of the cooling tower’s geometry. The critical wind speed and seismic vibrations versus height curve is observed to be similar to the Euler buckling curve. There is an assumed diameter to total height ratio of about 1.15 instead of 1.5 for any cooling tower at which the critical wind speed is maximum. The critical wind speed varies linearly with the cooling system thickness and non-linearly with all diameter ratios. A linear eigen value vibration, parametric analysis is expressed for various cooling tower shell geometries to analyse trends in the free vibration response (natural frequencies and mode shapes). The forced response of the cooling tower to various forcing frequencies of wind and seismic vibrations is analysed using the mode analysis method using Staad.pro software. The shells are subjected to increasing wind gust periods of an equivalent speed to get the trends within the forced vibration response. In a systematic ladder manner, the cooling tower geometry is changed to obtain the free and forced vibration behaviour. The natural frequencies and their corresponding for the four different modes reduce with increasing height based on the loads applied. They are generally invariant with the peak to top diameter ratio, but the bandwidth increases with increasing height to top diameter ratio. The static response frequencies and their corresponding generally increase with increasing height as well as the height to base diameter ratios. The static response frequency generally decreases with decreasing forcing frequency.. The findings can be used as a basis for further research and establishment of conceptual design guidelines when considering stability, free and forced vibration cooling tower_behaviour.
Suggested Citation
Mohd Atif Hussain & Rashmi Sakalle, 2021.
"Seismic and Wind Analysis of Natural Draught Cooling Tower with Change in Dimensional Ratio,"
Int J Sci Res Civil Engg, International Journal of Scientific Research in Civil Engineering, vol. 5(2), pages 92-103, October.
Handle:
RePEc:jcq:ijsrce:v5:y2021:i2:id:400
DOI: 10.32628/IJSRCE215221
Note: Article URL: https://ijsrce.com/home/article/view/IJSRCE215221
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:jcq:ijsrce:v5:y2021:i2:id:400. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Pankaj Sharma (email available below). General contact details of provider: https://ijsrce.com/home .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.