Author
Listed:
- Dae Uk Shin
(Department of Architecture & Building Engineering, Kunsan National University, Gunsan 54150, Republic of Korea)
- Nam-Kyu Park
(Department of Interior Design, University of Florida, Gainesville, FL 32611, USA)
Abstract
The WELL Building Standard (WELL) is a certification system designed to enhance occupant health and well-being in indoor environments. Conventional building energy-saving strategies typically rely on fixed temperature setpoint adjustments, which may conflict with WELL thermal comfort requirements. However, achieving high energy efficiency remains essential. This study uses a quantitative evaluation framework with TRNSYSs to examine the effectiveness of integrating load reset control (LRC) into simultaneous heating and cooling (SHC) systems. It compares LRC with conventional fixed setpoint (SP) and predicted mean vote (PMV) control strategies, based on WELL’s thermal comfort criteria (maintaining the PMV between −0.5 and +0.5). Six simulation cases were analyzed, considering radiant (RAD) and convection (CONV) terminals. The results indicate that radiant terminals provide more stable PMV performance while consuming less energy than convection terminals, demonstrating better compliance with WELL objectives. Although PMV control achieves the highest thermal comfort, it substantially increases energy consumption. In contrast, LRC emerges as an optimal strategy, effectively balancing the energy efficiency of SP control with the comfort of PMV control. The RAD-LRC configuration delivers the best overall performance. It achieves higher thermal comfort than SP, with comparable energy consumption, making it a highly practical approach for modern building energy management.
Suggested Citation
Dae Uk Shin & Nam-Kyu Park, 2026.
"Effectiveness of Load Reset Control in Simultaneous Heating and Cooling Systems Under WELL Thermal Comfort Criteria,"
Sustainability, MDPI, vol. 18(9), pages 1-24, April.
Handle:
RePEc:gam:jsusta:v:18:y:2026:i:9:p:4290-:d:1928933
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jsusta:v:18:y:2026:i:9:p:4290-:d:1928933. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.