IDEAS home Printed from https://ideas.repec.org/a/gam/jsusta/v18y2026i7p3491-d1912814.html

Two-Level Source-Grid-Load-Storage Preventive Resilience for Power Systems with Multiple Offshore Wind Farms Under Typhoon Scenarios

Author

Listed:
  • Qiuhui Chen

    (Faculty of Electrical Engineering, Shanghai University of Electric Power, Shanghai 200090, China
    Offshore Wind Power Research Institute, Shanghai University of Electric Power, Shanghai 200090, China)

  • Junhao Gong

    (Faculty of Electrical Engineering, Shanghai University of Electric Power, Shanghai 200090, China
    Offshore Wind Power Research Institute, Shanghai University of Electric Power, Shanghai 200090, China)

  • Xiangjing Su

    (Faculty of Electrical Engineering, Shanghai University of Electric Power, Shanghai 200090, China
    Offshore Wind Power Research Institute, Shanghai University of Electric Power, Shanghai 200090, China)

  • Fengyong Li

    (College of Computer Science and Technology, Shanghai University of Electric Power, Shanghai 200090, China)

Abstract

Typhoon-induced extreme weather poses a severe threat to power systems with high offshore wind penetration. Source-side wind turbine tripping and grid-side transmission line failures are likely to occur simultaneously, which may trigger cascading outages and large-scale load shedding. A multi-level source-grid-load-storage preventive resilience dispatch strategy is proposed. A typhoon spatiotemporal evolution model is first established based on the Batts gradient wind model. Failure probability models for offshore wind turbines and overhead transmission lines are developed while considering strong wind and lightning strike effects. The most probable and severe fault scenario is identified using an entropy-based quantification method. A two-stage robust preventive dispatch model is subsequently formulated. In the day-ahead stage, unit commitment, multi-type reserve allocation, and pumped storage scheduling are optimized at a 1 h resolution. In the real-time stage, combined wind-storage systems are coordinated at a 10 min resolution to accommodate rapid wind power ramps caused by high-wind shutdown events. The model is reformulated through Lagrangian duality and solved by the Benders decomposition algorithm. Case studies on a modified IEEE-RTS 24-bus system with three offshore wind farms demonstrate that the proposed strategy reduces wind curtailment by 66.3%, load shedding by 74.6%, and total cost by 14.8% compared with the case without energy storage. The combined operation cost of storage resources accounts for only 3.1% of the total cost, confirming its favorable cost-effectiveness for resilience enhancement. The proposed strategy contributes to the sustainable integration of offshore wind energy by ensuring a reliable power supply during extreme weather events.

Suggested Citation

  • Qiuhui Chen & Junhao Gong & Xiangjing Su & Fengyong Li, 2026. "Two-Level Source-Grid-Load-Storage Preventive Resilience for Power Systems with Multiple Offshore Wind Farms Under Typhoon Scenarios," Sustainability, MDPI, vol. 18(7), pages 1-27, April.
  • Handle: RePEc:gam:jsusta:v:18:y:2026:i:7:p:3491-:d:1912814
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/2071-1050/18/7/3491/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/2071-1050/18/7/3491/
    Download Restriction: no
    ---><---

    More about this item

    Keywords

    ;
    ;
    ;
    ;
    ;
    ;
    ;
    ;

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jsusta:v:18:y:2026:i:7:p:3491-:d:1912814. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.