Thermal bridges at window installations significantly influence the energy performance and indoor comfort of buildings, particularly in nearly zero energy buildings (nZEB). This study investigates the impact of window mounting-position on thermal-bridge intensity at window-to-wall junctions using finite element method (FEM) simulations of representative junction configurations. Mounting depth, frame alignment relative to the insulation layer, and junction detailing were systematically varied to quantify their effect on linear thermal transmittance ( ψ -values) and internal-surface temperatures. The results show that relatively small changes in mounting position can markedly reduce thermal-bridge effects; the most effective strategy combines installing the window within the insulation layer at an optimal depth of 7–12 cm. Across the studied configurations, ψ decreased from traditional installation values of 0.27 W/(m·K) to 0.02 W/(m·K) for installation in the insulation layer, and with frame overlap and frame extenders, the ψ -value can be further reduced, reaching 0.005 W/(m·K) in the best case. Applying external insulation increases the minimum internal-surface temperature by at least 2 °C compared with cases without frame covering. In the case study of a historical building retrofitted to Passive House (PH) standard, installing windows in the insulation layer reduced annual heating demand from 32 kWh/m 2 to 24 kWh/m 2 . The additional investment is economically justified, with a simple payback period of about 25 years, decreasing to around 20 years assuming a 3% annual increase in energy prices. These findings demonstrate that optimised window positioning is an effective and economically viable measure to improve the energy performance, durability, and sustainability of high-performance buildings.

Suggested Citation

  • Staņislavs Gendelis & Petro Shamilov & Andris Jakovičs & Pavlo Biriukovych & Sergii Khmelenko, 2026. "Numerical Optimisation of Window Installation Thermal Bridges for Sustainable Buildings: The Impact of Mounting Position," Sustainability, MDPI, vol. 18(7), pages 1-22, April.
  • Handle: RePEc:gam:jsusta:v:18:y:2026:i:7:p:3474-:d:1912534
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/2071-1050/18/7/3474/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/2071-1050/18/7/3474/
    Download Restriction: no
    ---><---

    More about this item

    Keywords

    ;
    ;
    ;
    ;
    ;
    ;
    ;
    ;

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jsusta:v:18:y:2026:i:7:p:3474-:d:1912534. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.