Author
Listed:
- Yichong Zhang
(The Electrical Engineering College, Guizhou University, Guiyang 550025, China)
- Huajun Zheng
(The Electrical Engineering College, Guizhou University, Guiyang 550025, China)
- Xufeng Yuan
(The Electrical Engineering College, Guizhou University, Guiyang 550025, China)
- Chao Zhang
(The Electrical Engineering College, Guizhou University, Guiyang 550025, China)
- Wei Xiong
(The Electrical Engineering College, Guizhou University, Guiyang 550025, China)
Abstract
The transition towards sustainable energy systems is critically dependent on the reliable integration of renewable energy sources into the power grid. With the increasing penetration of renewable generation, hybrid grid-connected systems comprising grid-following (GFL) and grid-forming (GFM) converters have become essential in modern power stations. This paper addresses a key challenge to sustainable grid operation: maintaining stability and power delivery during grid faults. When faults cause voltage sags at the point of common coupling (PCC), different low-voltage ride-through (LVRT) strategies significantly impact both the voltage support capability and the active power transmission capacity, which are vital for a stable and resilient energy supply. To address this, the paper proposes a coordinated LVRT strategy for GFL/GFM converters that adapts to varying grid requirements, thereby promoting sustainable grid integration. First, the topology and control strategies of the hybrid system are briefly described. The conventional LVRT control strategies for both GFL and GFM converters are then improved. Based on the severity of the grid voltage sag, the converters’ active and reactive power output are adaptively adjusted. This dual-function approach not only effectively limits fault currents, protecting sensitive equipment, but also prioritizes the continuous transmission of active power, thereby minimizing the loss of renewable generation during faults and supporting grid stability. Subsequently, through an analysis of the voltage and active power characteristics of different LVRT modes, a coordinated strategy is designed. Unlike single-converter LVRT control, the proposed method flexibly selects and adjusts control modes to meet specific grid code requirements, ensuring robust voltage support and maximizing the utilization of clean energy even under adverse conditions. Finally, the effectiveness of this coordinated control strategy in ensuring a sustainable and resilient grid connection is validated through MATLAB R2022b/Simulink simulations.
Suggested Citation
Yichong Zhang & Huajun Zheng & Xufeng Yuan & Chao Zhang & Wei Xiong, 2026.
"Coordinated Low-Voltage Ride-Through Strategy for Hybrid Grid-Forming and Grid-Following Converter Interconnected Grid Systems,"
Sustainability, MDPI, vol. 18(7), pages 1-21, March.
Handle:
RePEc:gam:jsusta:v:18:y:2026:i:7:p:3246-:d:1907072
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jsusta:v:18:y:2026:i:7:p:3246-:d:1907072. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.