Abstract
Indoor air quality (IAQ) in educational buildings plays a critical role in the health, cognitive performance, and well-being of occupants. Aging university facilities often rely on outdated ventilation systems that are not designed to meet current demands or respond to dynamic occupancy levels. This study investigates the performance and feasibility of various advanced ventilation strategies in comparison to an existing balanced mechanical ventilation (BMV) system in a university classroom accommodating 100 students. Using a Dynamic Building Energy Simulation Program, simulations were conducted to evaluate IAQ (using CO 2 levels), energy consumption, and thermal comfort under three retrofitting scenarios: BMV, demand-controlled ventilation (DCV), and hybrid ventilation combining natural and mechanical airflow. The simulations indicate that DCV cuts annual HVAC energy use by 33% relative to the baseline, while the hybrid strategy achieves the greatest reduction of 42% and maintains CO 2 levels and thermal comfort within recommended limits. Although hybrid systems provide seasonal advantages, their complexity may limit applicability. In addition to technical analysis, this study also explores the financial and tax-related challenges associated with retrofitting ventilation systems in university buildings. Investment payback periods, operational costs, and potential tax incentives are discussed to evaluate economic viability. Overall, the endorse hybrid ventilation as the most cost-effective strategy where mixed-mode control is feasible, and DCV as a practical alternative for buildings unable to employ natural ventilation.
Suggested Citation
Cihan Turhan & Yousif Abed Saleh Saleh & Burcu Turhan, 2026.
"Simulation-Based Optimization of HVAC Systems in Aging Educational Facilities: Addressing IAQ Challenges Through Retrofitting,"
Sustainability, MDPI, vol. 18(6), pages 1-23, March.
Handle:
RePEc:gam:jsusta:v:18:y:2026:i:6:p:3079-:d:1900130
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jsusta:v:18:y:2026:i:6:p:3079-:d:1900130. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.