Author
Listed:
- Mokabbera Billah
(Faculty of Engineering, American International University-Bangladesh, Dhaka 1229, Bangladesh)
- Shameem Ahmad
(Department of Electrical and Electronic Engineering, BSRM School of Engineering, BRAC University, Dhaka 1212, Bangladesh)
- Chowdhury Akram Hossain
(Faculty of Engineering, American International University-Bangladesh, Dhaka 1229, Bangladesh)
- Md. Rifat Hazari
(Faculty of Engineering, American International University-Bangladesh, Dhaka 1229, Bangladesh)
- Minh Quan Duong
(Electrical Engineering Faculty, The University of Da Nang—University of Science and Technology, Da Nang 550000, Vietnam)
- Gabriela Nicoleta Sava
(Faculty of Power Engineering, National University of Science and Technology POLITEHNICA Bucharest, 060042 Bucharest, Romania)
- Emanuele Ogliari
(Department of Energy, Politecnico di Milano, Via Giuseppe La Masa, 34, 20156 Milan, Italy)
Abstract
Low-voltage ride-through (LVRT) capability is essential for grid-connected photovoltaic (PV) systems, especially as rising renewable integration challenges grid stability during voltage disturbances. Existing LVRT methods often target isolated control functions, leading to limited system resilience. This paper presents a unified control strategy integrating DC-link voltage regulation, reactive power injection, and overvoltage mitigation using a coordinated fuzzy logic framework. The proposed architecture employs a cascaded control structure comprising an outer voltage loop and an inner current loop with feed-forward decoupling, synchronized via a Synchronous Reference Frame Phase-Locked Loop (SRF-PLL). At its core is a dual-input, single-output Fuzzy Logic Controller (FLC), featuring optimized membership functions and dynamic rule-based logic to manage multiple control objectives during grid faults. The proposed FLC-based unified LVRT controller for grid-tied PV system was implemented and validated for both symmetrical and asymmetrical fault conditions in MATLAB/Simulink 2023b platform. The proposed FLC-based LVRT controller achieves voltage sag compensation of 97.02% and 98.4% for symmetrical and asymmetrical faults, respectively, outperforming conventional PI control, which achieves 94.02% and 96.5%. The system maintains a stable DC-link voltage of 800 V and delivers up to 78% reactive power support during faults. Fault detection and recovery are completed within 200 ms, complying with Bangladesh grid code requirements. This integrated fuzzy logic approach offers a significant advancement for enhancing grid stability in high-renewable environments and supports reliable renewable utilization, and more sustainable grid operation in developing regions.
Suggested Citation
Mokabbera Billah & Shameem Ahmad & Chowdhury Akram Hossain & Md. Rifat Hazari & Minh Quan Duong & Gabriela Nicoleta Sava & Emanuele Ogliari, 2026.
"Fuzzy Logic-Based LVRT Enhancement in Grid-Connected PV System for Sustainable Smart Grid Operation: A Unified Approach for DC-Link Voltage and Reactive Power Control,"
Sustainability, MDPI, vol. 18(5), pages 1-22, March.
Handle:
RePEc:gam:jsusta:v:18:y:2026:i:5:p:2448-:d:1876916
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jsusta:v:18:y:2026:i:5:p:2448-:d:1876916. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.