Author
Listed:
- Sylwia Szczęśniak
(Department of Air-Conditioning, Heating, Gas Engineering and Air Protection, Faculty of Environmental Engineering, Wroclaw University of Science and Technology, 50-377 Wroclaw, Poland)
- Juliusz Walaszczyk
(Department of Air-Conditioning, Heating, Gas Engineering and Air Protection, Faculty of Environmental Engineering, Wroclaw University of Science and Technology, 50-377 Wroclaw, Poland)
- Agnieszka Trusz
(Department of Environmental Biology and Air Protection, Faculty of Environmental Engineering, Wroclaw University of Science and Technology, 50-377 Wroclaw, Poland)
- Katarzyna Piekarska
(Department of Environmental Biology and Air Protection, Faculty of Environmental Engineering, Wroclaw University of Science and Technology, 50-377 Wroclaw, Poland)
Abstract
Microbiological contamination in public buildings is closely linked to human presence, such as airborne bacteria, fungi, and particulate matter, which strongly influence indoor air quality (IAQ). This study examined the distribution of microorganisms in a museum building in relation to time of day, air-handling unit (AHU) type, and ventilation operating mode. Exhibition rooms without natural light relied entirely on a central heating, ventilation and air conditioning (HVAC) system. Microbiological contamination was assessed using Koch’s passive sedimentation method over a 24 h cycle for two AHUs (I and III) and selected rooms, while CO 2 levels were monitored as indicators of occupancy and ventilation demand in line with EN 16798-1:2019 and ASHRAE 62.1-2022. Although the demand-controlled ventilation system increased the outdoor air fraction from 40% to 70–100% during peak visitor density, localized increases in microbial contamination occurred. AHU I showed higher loads of Staphylococcus sp. and fungi, while AHU III exhibited pronounced fungal peaks influenced by elevated humidity from an open water reservoir. Psychrophilic bacteria reached 140–230 CFU·m −3 , mesophilic bacteria 230–320 CFU·m −3 , and fungi up to 740 CFU·m −3 . Most CFU values remained below commonly referenced upper limits (<1000 CFU·m −3 ), but several peaks exceeded lower recommended thresholds, indicating a need for improvements. Enhanced filtration, humidity control, increased airflow during high occupancy, and reducing moisture sources in AHUs may mitigate microbial growth and improve IAQ in public buildings.
Suggested Citation
Sylwia Szczęśniak & Juliusz Walaszczyk & Agnieszka Trusz & Katarzyna Piekarska, 2026.
"Microbiological Air Quality in Windowless Exhibition Spaces with Centralized Air-Conditioning and Air Recirculation—Pilot Study,"
Sustainability, MDPI, vol. 18(3), pages 1-17, February.
Handle:
RePEc:gam:jsusta:v:18:y:2026:i:3:p:1656-:d:1858344
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jsusta:v:18:y:2026:i:3:p:1656-:d:1858344. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.