IDEAS home Printed from https://ideas.repec.org/a/gam/jsusta/v18y2026i3p1308-d1850653.html

Numerical Simulation and Experimental Study on Systematic Thermal Bridges of High-Performance Sandwich Insulation Wall Panels: Implications for Building Sustainability

Author

Listed:
  • Yi Zhang

    (China Academy of Building Research Co., Ltd., Beijing 100013, China)

  • Qinqin Deng

    (China Academy of Building Research Co., Ltd., Beijing 100013, China)

  • Lixin Sun

    (China Academy of Building Research Co., Ltd., Beijing 100013, China
    State Key Laboratory of Building Safety and Built Environment, Beijing 100013, China)

  • Chu Zhao

    (State Key Laboratory of Building Safety and Built Environment, Beijing 100013, China)

  • Yu Zou

    (China Academy of Building Research Co., Ltd., Beijing 100013, China)

  • Weijun Li

    (Shanxi Low-Carbon Building Laboratory Co., Ltd., Taiyuan 030600, China)

Abstract

As a prevalent integrated structure-insulation system, sandwich insulation wall panels have emerged as a critical structural configuration for zero- and nearly zero-energy green buildings, owing to their high construction efficiency and superior thermal insulation performance which directly aligns with the core goals of sustainability and sustainable energy utilization in the built environment. However, connectors penetrate the insulation layer and form systematic thermal bridges, which cause substantial heat loss and become a key bottleneck limiting further improvement in the overall thermal performance of wall systems. This study established three-dimensional numerical models of sandwich insulation wall panels with four typical connectors (fiber-reinforced polymers (FRPs), clamp-type stainless steel, plate-type stainless steel, and truss-type stainless steel) using Ansys Fluent 2021R1. The model reliability was verified by calibrated hot-box experiments, with relative errors between simulation and experimental results ranging from 2.1% to 16.1%. Systematic numerical simulations were then performed to investigate the effects of connector type, insulation material, climate zone, inner–outer temperature difference, connector quantity, and wall dimensions on the thermal bridge effect. The results indicated that FRP connectors caused the minimal heat flux increment (only 0.27%), followed by clamp-type stainless steel connectors (9.59%), while plate-type and truss-type stainless steel connectors led to significant increments (27.17% and 27.62%, respectively). The lower the heat transfer coefficient (K-value) of the wall was, the more prominent the connector-induced thermal bridge effect was. Within the typical temperature difference range, the heat flux increment of each connector remained stable, and polyurethane (PU) insulation exhibited a more significant inhibitory effect on thermal bridges than extruded polystyrene (XPS) under the same K-value. Linear fitting formulas for the relationship between wall K-value/temperature difference and the heat flux correction coefficient were derived, with high goodness-of-fit. The maximum impact of connectors on wall thermal performance did not exceed 30%. This study provides theoretical support and design references for the selection of connectors, material optimization, and thermal performance calculation of sandwich insulation wall panels, contributing to the promotion of energy-saving building envelope technologies.

Suggested Citation

  • Yi Zhang & Qinqin Deng & Lixin Sun & Chu Zhao & Yu Zou & Weijun Li, 2026. "Numerical Simulation and Experimental Study on Systematic Thermal Bridges of High-Performance Sandwich Insulation Wall Panels: Implications for Building Sustainability," Sustainability, MDPI, vol. 18(3), pages 1-25, January.
  • Handle: RePEc:gam:jsusta:v:18:y:2026:i:3:p:1308-:d:1850653
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/2071-1050/18/3/1308/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/2071-1050/18/3/1308/
    Download Restriction: no
    ---><---

    More about this item

    Keywords

    ;
    ;
    ;
    ;
    ;
    ;

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jsusta:v:18:y:2026:i:3:p:1308-:d:1850653. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.