Author
Listed:
- Mohammad Ahmad Hussein Khataybeh
(Department of Architecture, Faculty of Architecture and Design, Istanbul Aydın University, 34295 Istanbul, Türkiye)
- Alpay Akgüç
(Department of Architecture, Faculty of Architecture, Istanbul Bilgi University, 34060 Istanbul, Türkiye)
- Dilek Yasar
(Department of Interior Architecture, Faculty of Architecture and Design, Istanbul Aydın University, 34295 Istanbul, Türkiye)
Abstract
Traditional windcatchers are often discussed as passive cooling devices for hot–arid climates, yet their sustainability performance under contemporary comfort-controlled operation remains insufficiently understood. This study evaluates the energy and load-based carbon implications of integrating a windcatcher into a high-thermal-mass courtyard house in Şanlıurfa, Türkiye. A combined DesignBuilder v6.1/EnergyPlus v8.2 and CFD-based assessment was used: annual heating and cooling loads were calculated through EnergyPlus-based building energy simulation, while CFD analyses were used to interpret representative airflow behavior and localized thermal effects within the semi-open iwan. Scenarios varied operational schedule, geometry, material configuration, ventilation openings, and water pool integration. The results show strongly context-dependent performance rather than uniform energy or carbon benefit. Continuous operation weakened annual performance, whereas seasonal operation produced more balanced outcomes. The P.1 configuration produced the lowest total annual energy demand among the tested scenarios, decreasing total demand from 70,929.99 to 70,806.65 kWh/a, corresponding to a reduction of 123.34 kWh/a or 0.17% relative to the baseline. However, this limited reduction was accompanied by a 6.02% increase in cooling demand and a 2.52% decrease in heating demand. Consequently, the total load-based carbon indicator increased from 18.32 to 18.60 tCO 2 /year, corresponding to an increase of 0.28 tCO 2 /year or 1.53%. CFD results indicate that the semi-open iwan geometry and its orientation relative to prevailing winds constrained airflow effectiveness and limited the transfer of local cooling effects to conditioned zones. This study demonstrates that vernacular passive systems should be evaluated through integrated annual energy, airflow, and load-based carbon analyses before being adopted in sustainable renovation or climate-responsive design.
Suggested Citation
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jsusta:v:18:y:2026:i:14:p:7283-:d:1992672. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager The email address of this maintainer does not seem to be valid anymore. Please ask MDPI Indexing Manager to update the entry or send us the correct address
(email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.