Development of a DC-Coupled Three-Phase Grid-Connected Solar Photovoltaic Integrated Battery Energy Storage System with Peak Shaving and Valley-Filling Control

Author

Listed:
  • Kuei-Hsiang Chao

    (Department of Electrical Engineering, National Chin-Yi University of Technology, Taichung 41170, Taiwan)

  • Yu-Hua Wang

    (Department of Electrical Engineering, National Chin-Yi University of Technology, Taichung 41170, Taiwan)

  • Chang-De Wu

    (Department of Electrical Engineering, National Chin-Yi University of Technology, Taichung 41170, Taiwan)

Abstract

This study addresses the power dispatching of a DC-coupled three-phase grid-connected photovoltaic (PV) and energy storage-integrated system by proposing a peak shaving and valley-filling control architecture based on time-of-use (TOU) pricing. This research involves achieving maximum power-point tracking (MPPT) for PVMAs using a boost converter combined with the perturb and observe (P&O) method. A lithium-iron phosphate battery pack is integrated into the DC link via a bidirectional buck-boost converter, where charging and discharging control is executed according to peak and off-peak periods to regulate and stabilize the DC link voltage. Furthermore, bidirectional power flow control for peak and off-peak electricity consumption is realized using hysteresis current control and sinusoidal pulse-width modulation (SPWM) technologies within a smart inverter. By integrating the aforementioned power control architecture, the grid system can store energy from the utility during off-peak hours and release the stored energy during peak hours to reduce the load demand on the utility side. Initially, a simulation environment was established using Matlab/Simulink (2024b version) software, followed by control verification of the proposed system on a physical platform. The simulation and experimental results confirm that the integrated control architecture can precisely control the system’s DC link voltage at 800 V and stabilize the grid-connected AC voltage at an effective value (RMS) of 380 V. Moreover, under conditions of peak/off-peak switching and load variations, the system effectively demonstrates its stability and efficacy in performing valley filling and peak shaving. The proposed strategy achieves a power factor above 0.99 and a total harmonic distortion (THD) below 5%, regulates the DC-link voltage at 800 V with a steady-state error within 1.75%, and prevents up to 66.4 kWh of over-contract energy consumption per day under a 35 kW contract capacity, thereby contributing to sustainable energy management and economic savings.

Suggested Citation

  • Kuei-Hsiang Chao & Yu-Hua Wang & Chang-De Wu, 2026. "Development of a DC-Coupled Three-Phase Grid-Connected Solar Photovoltaic Integrated Battery Energy Storage System with Peak Shaving and Valley-Filling Control," Sustainability, MDPI, vol. 18(13), pages 1-27, July.
  • Handle: RePEc:gam:jsusta:v:18:y:2026:i:13:p:6738-:d:1981972
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/2071-1050/18/13/6738/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/2071-1050/18/13/6738/
    Download Restriction: no
    ---><---

    More about this item

    Keywords

    ;
    ;
    ;
    ;
    ;
    ;
    ;
    ;
    ;
    ;

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jsusta:v:18:y:2026:i:13:p:6738-:d:1981972. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager The email address of this maintainer does not seem to be valid anymore. Please ask MDPI Indexing Manager to update the entry or send us the correct address (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.