Sustainable Continuous-Flow Wastewater Disinfection Using an Automated Electroporation-Based System

Author

Listed:
  • Iosif Lingvay

    (Research & Development Institute for Environmental Protection Technologies and Equipment (ICPE Bistrița S.A.), 420080 Bistrița, Romania)

  • Daniela Simina Ștefan

    (Faculty of Chemical Engineering and Biotechnologies, National University of Science and Technology POLITEHNICA Bucharest, 313 Splaiul Independenței, Sector 6, 060042 Bucharest, Romania)

  • Attila Tókos

    (Research & Development Institute for Environmental Protection Technologies and Equipment (ICPE Bistrița S.A.), 420080 Bistrița, Romania)

  • Camelia Ungureanu

    (Faculty of Chemical Engineering and Biotechnologies, National University of Science and Technology POLITEHNICA Bucharest, 313 Splaiul Independenței, Sector 6, 060042 Bucharest, Romania)

  • Ana Iulia Ștefan

    (Regina Maria Dental Hospital, 71 Cozia Street, 077190 Timișoara, Romania)

  • Csaba Bartha

    (Research & Development Institute for Environmental Protection Technologies and Equipment (ICPE Bistrița S.A.), 420080 Bistrița, Romania)

Abstract

The paper presents an automated, remotely controlled installation for the continuous-flow disinfection of treated wastewater. The proposed solution ensures the inactivation of microorganisms without heating the fluid and without the use of chemical disinfectants, thus reducing the environmental impact and resource consumption associated with conventional disinfection methods. The destruction of microorganisms is achieved by applying high-intensity electrical pulses, which cause irreversible permeabilization of cell membranes through the phenomenon of electroporation. The installation is fully automated and based on a closed-loop control system, in which a programmable logic controller (PLC) acquires data from specialized sensors and automatically regulates the process variables according to the measured operating conditions. The system implements a closed-loop control strategy, optimizing the amplitude, duration and frequency of the electrical pulses depending on the characteristics of the treated fluid and the working flow rate. By eliminating chemical reagents and limiting thermal effects, the proposed technology contributes to reducing energy consumption and increasing the sustainability of the disinfection process. The integration of electroporation with modern automation and monitoring solutions supports the implementation of circular economy principles and the development of sustainable strategies for the management and reuse of treated wastewater. The proposed PLC-SCADA architecture enables adaptive real-time control of the disinfection process by continuously adjusting pulse amplitude, duration, and repetition frequency according to wastewater characteristics and flow conditions. Compared with conventional chemical disinfection methods, the system eliminates the need for chemical reagents and minimizes the formation of secondary pollutants. In addition, the continuous-flow configuration facilitates integration into existing wastewater treatment infrastructures while supporting sustainable and energy-efficient operation.

Suggested Citation

  • Iosif Lingvay & Daniela Simina Ștefan & Attila Tókos & Camelia Ungureanu & Ana Iulia Ștefan & Csaba Bartha, 2026. "Sustainable Continuous-Flow Wastewater Disinfection Using an Automated Electroporation-Based System," Sustainability, MDPI, vol. 18(13), pages 1-13, June.
  • Handle: RePEc:gam:jsusta:v:18:y:2026:i:13:p:6583-:d:1978371
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/2071-1050/18/13/6583/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/2071-1050/18/13/6583/
    Download Restriction: no
    ---><---

    More about this item

    Keywords

    ;
    ;
    ;
    ;
    ;
    ;
    ;
    ;
    ;

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jsusta:v:18:y:2026:i:13:p:6583-:d:1978371. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager The email address of this maintainer does not seem to be valid anymore. Please ask MDPI Indexing Manager to update the entry or send us the correct address (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.