Restaurants combine long opening hours, catering demand, kitchen ventilation, DHW, and mixed-fuel cooking loads, making their decarbonisation different from generic commercial retrofit. For small- and medium-sized enterprise (SME) hospitality premises, this makes the transition to net-zero operation a distinct sustainability challenge because a large, process-driven share of demand lies outside conventional building-fabric and building-services retrofit. This single-case study develops a whole-building utility-calibrated OpenStudio/EnergyPlus model for Beit El Zaytoun, a 655.82 m 2 restaurant in Park Royal, London. Monthly electricity and gas data for June 2024–May 2025 were used to calibrate the baseline at whole-building level. Standalone and cumulative scenarios tested insulation, low-emissivity double glazing, LED lighting and controls, ASHP service scenarios, and an 11 kWp PV array. Baseline demand was 413,895 kWh/yr, equivalent to 631.1 kWh/m 2 ·yr and 75,020 kgCO 2 e/yr. The lowest-net-energy analytical package reduced net imported energy to 314,734 kWh/yr and operational carbon to 56,700 kgCO 2 e/yr, a retained 24.0% reduction on the source reporting basis; this package is treated as an analytical bound rather than as a final design recommendation because it excludes cooling. The model-derived residual process load, kitchen and catering gas plus kitchen, and back-of-house electricity remained 233,920 kWh/yr across building-focused scenarios. The Residual-Load Index (RLI) rose from 0.57 to 0.74; with ±15% process-load allocation uncertainty, the optimised RLI range was 0.63–0.85, so the post-retrofit balance remained process-load dominated. The case demonstrates a practical decarbonisation ceiling likely to recur in similar high-process-load hospitality premises: fabric, lighting, heat electrification, and PV are necessary but insufficient without catering-equipment, cooking-fuel, kitchen-ventilation, refrigeration-control, sub-metering, and demand-response strategies. The paper contributes whole-building utility-calibrated quantitative evidence and a transferable RLI metric for sub-sector-specific sustainable retrofit policy, and the net-zero transition of SME food-service premises.
Suggested Citation
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jsusta:v:18:y:2026:i:13:p:6517-:d:1976320. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager The email address of this maintainer does not seem to be valid anymore. Please ask MDPI Indexing Manager to update the entry or send us the correct address
(email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.