IDEAS home Printed from https://ideas.repec.org/a/gam/jsusta/v18y2026i10p4971-d1943454.html

Sustainable District-Heating Transition in Poland: The Case of the City of Ustka

Author

Listed:
  • Ireneusz Zagrodzki

    (EMPEC Ustka, Bałtycka 5a Street, 76-270 Ustka, Poland)

  • Mateusz Bryk

    (Energy Conversion Department, Institute of Fluid Flow Machinery, Polish Academy of Sciences, 80-231 Gdańsk, Poland)

  • Piotr Józef Ziółkowski

    (Energy Conversion Department, Institute of Fluid Flow Machinery, Polish Academy of Sciences, 80-231 Gdańsk, Poland)

  • Tomasz Kowalczyk

    (Energy Conversion Department, Institute of Fluid Flow Machinery, Polish Academy of Sciences, 80-231 Gdańsk, Poland)

  • Pedro Jesus Cabrera Santana

    (Department of Mechanical Engineering, University of Las Palmas de Gran Canaria, Campus de Tafira s/n, 35001 Las Palmas de Gran Canaria, Spain)

  • Janusz Badur

    (Energy Conversion Department, Institute of Fluid Flow Machinery, Polish Academy of Sciences, 80-231 Gdańsk, Poland)

Abstract

The energy transition of district heating systems in Poland requires the simultaneous consideration of energy efficiency, operating costs, technical feasibility, and local environmental constraints. This study addresses an identified gap in the literature by combining real operational time series from a municipal district heating system with time-resolved market signals and site-specific resource constraints in a single OPEX-based operational screening framework. A case study is conducted for the city of Ustka using a configuration-based comparison of hybrid supply systems that include a gas-fired combined heat and power (CHP) unit, air-source and ground-source heat pumps, thermal energy storage, and a peak-load boiler. The optimisation model was implemented in MS Excel using the GRG Nonlinear algorithm (Solver) and was driven by the district heating operational data for 2021–2022 together with electricity and natural gas prices from the Polish Power Exchange day-ahead market (TGE RDN), evaluated under both hourly and daily settlement assumptions. The results indicate an optimal capacity split of 1.2 MWel/1.3 MWth for the CHP unit and 1.5 MWel/3.0 MWth for the heat pump system, supported by a required peak boiler capacity of 8.23 MWth. Within the adopted OPEX-based assessment, the lowest value of the unit heat generation indicator was obtained for the CHP-led configuration with combined ground-source and air-source heat pumps (38.45–38.55 PLN/GJ). A distinctive element of the study is the explicit verification of whether an operationally favourable configuration remains practically feasible when local resource constraints are considered. The site assessment indicates limited practical feasibility of the borehole heat exchanger at the analysed location in Ustka, showing that the lowest OPEX result should not be interpreted as a final investment recommendation. The study provides a replicable approach for the Polish district heating operators to screen hybrid transition pathways under real market conditions and to avoid technology choices that are favourable in dispatch models but constrained in practice. From a sustainability perspective, the proposed framework supports more energy-efficient, resilient, and locally feasible district heating transition planning in municipal heat systems.

Suggested Citation

  • Ireneusz Zagrodzki & Mateusz Bryk & Piotr Józef Ziółkowski & Tomasz Kowalczyk & Pedro Jesus Cabrera Santana & Janusz Badur, 2026. "Sustainable District-Heating Transition in Poland: The Case of the City of Ustka," Sustainability, MDPI, vol. 18(10), pages 1-27, May.
  • Handle: RePEc:gam:jsusta:v:18:y:2026:i:10:p:4971-:d:1943454
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/2071-1050/18/10/4971/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/2071-1050/18/10/4971/
    Download Restriction: no
    ---><---

    More about this item

    Keywords

    ;
    ;
    ;
    ;
    ;
    ;
    ;
    ;
    ;
    ;

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jsusta:v:18:y:2026:i:10:p:4971-:d:1943454. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager The email address of this maintainer does not seem to be valid anymore. Please ask MDPI Indexing Manager to update the entry or send us the correct address (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.