IDEAS home Printed from https://ideas.repec.org/a/gam/jsusta/v18y2026i10p4667-d1937586.html

Study on the Indoor Thermal Environment of Prefabricated Railway Buildings in High-Altitude Cold Regions for Sustainable Development

Author

Listed:
  • Hui Li

    (School of Civil Engineering, Southwest Jiaotong University, Chengdu 610031, China
    China Railway First Survey & Design Institute Group Co., Ltd., Xi’an 710043, China)

  • Lintao Ma

    (School of Civil Engineering, Southwest Jiaotong University, Chengdu 610031, China)

  • Haojie Zhang

    (School of Civil Engineering, Southwest Jiaotong University, Chengdu 610031, China)

  • Zhixiang Yu

    (School of Civil Engineering, Southwest Jiaotong University, Chengdu 610031, China)

  • Hu Xu

    (School of Civil Engineering, Southwest Jiaotong University, Chengdu 610031, China)

Abstract

Prefabricated buildings offer high industrialization, construction efficiency, and sustainability benefits, making them particularly well suited for adverse construction conditions. As railway networks expand into western China’s high-altitude regions, prefabricated structures have been increasingly adopted for living quarters along railway lines in cold, high-altitude areas. This study proposes a method that accounts for thermal-bridge effects by using the average thermal transmittance coefficient K m and the linear thermal transmittance ψ calculated via two-dimensional steady-state simulations with PTemp software. The approach was validated against 48 h field measurements from a prefabricated building in Weinan: the model incorporating thermal bridges reduced the mean temperature error from 15.6% to 7.74%, confirming its accuracy. Using DeST software, the indoor thermal environment of a railway living-quarter building in the Ganzi region was simulated. Results show that south-facing rooms have an average temperature 2.3 °C higher than north-facing rooms and a 17.74% lower annual discomfort time. Building orientation, south-facing window-to-wall ratio, and envelope thermal transmittance significantly affect overall indoor temperature and energy consumption. The optimal orientation range is 15–45° west of south, and the least favorable range is 135–165°. A south-facing WWR of 0.35–0.45 and an exterior wall insulation thickness of 60–120 mm are recommended. For the typical high-altitude locations Litang, Batang, Qamdo, Nyingchi, Lhasa, and Ganzi, region-specific optimal parameters are provided: exterior wall K m values range from 0.10 to 0.65 W/(m 2 ·K) and window K values from 1.0 to 3.0 W/(m 2 ·K), depending on the local solar radiation and altitude. These findings offer quantitative design guidance for improving indoor thermal comfort and reducing energy use in prefabricated railway buildings on the western Sichuan and Tibetan plateaus.

Suggested Citation

  • Hui Li & Lintao Ma & Haojie Zhang & Zhixiang Yu & Hu Xu, 2026. "Study on the Indoor Thermal Environment of Prefabricated Railway Buildings in High-Altitude Cold Regions for Sustainable Development," Sustainability, MDPI, vol. 18(10), pages 1-27, May.
  • Handle: RePEc:gam:jsusta:v:18:y:2026:i:10:p:4667-:d:1937586
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/2071-1050/18/10/4667/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/2071-1050/18/10/4667/
    Download Restriction: no
    ---><---

    More about this item

    Keywords

    ;
    ;
    ;
    ;
    ;
    ;

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jsusta:v:18:y:2026:i:10:p:4667-:d:1937586. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.