IDEAS home Printed from https://ideas.repec.org/a/gam/jsusta/v17y2025i24p11036-d1814173.html

Optimal µ-PMU Placement and Voltage Estimation in Distribution Networks: Evaluation Through Multiple Case Studies

Author

Listed:
  • Asjad Ali

    (Advanced Lightning Power and Energy Research (ALPER), Department of Electrical and Electronic Engineering, Faculty of Engineering, Universiti Putra Malaysia, Serdang 43400, Selangor, Malaysia)

  • Noor Izzri Abdul Wahab

    (Advanced Lightning Power and Energy Research (ALPER), Department of Electrical and Electronic Engineering, Faculty of Engineering, Universiti Putra Malaysia, Serdang 43400, Selangor, Malaysia)

  • Mohammad Lutfi Othman

    (Advanced Lightning Power and Energy Research (ALPER), Department of Electrical and Electronic Engineering, Faculty of Engineering, Universiti Putra Malaysia, Serdang 43400, Selangor, Malaysia)

  • Rizwan A. Farade

    (Advanced Lightning Power and Energy Research (ALPER), Department of Electrical and Electronic Engineering, Faculty of Engineering, Universiti Putra Malaysia, Serdang 43400, Selangor, Malaysia)

  • Husam S. Samkari

    (Department of Electrical Engineering, University of Tabuk, Tabuk 47713, Saudi Arabia
    Artificial Intelligence and Sensing Technologies Research Center, University of Tabuk, Tabuk 47713, Saudi Arabia)

  • Mohammed F. Allehyani

    (Department of Electrical Engineering, University of Tabuk, Tabuk 47713, Saudi Arabia)

Abstract

This study optimizes the placement of μ-PMUs using the BPSO and BGWO algorithms for the IEEE 33-bus and 69-bus systems, with a focus on minimizing deployment costs while ensuring robust system observability. Three case studies are analysed: Case 1 (normal conditions), Case 2 (single μ-PMU outage), and Case 3 (Zero Injection Buses, ZIBs). In Case 1, both algorithms identified 24 μ-PMUs as the optimal placement for the IEEE 69-bus system, achieving the minimum PMUs required for full observability. For Case 2, redundancy requirements increased the μ-PMU count to 24 μ-PMUs for the IEEE 33-bus system and 51 μ-PMUs for the IEEE 69-bus system, ensuring full observability even under a single μ-PMU failure. Case 3, leveraging Zero Injection Buses (ZIBs), reduced the μ-PMU count to 20 μ-PMUs for both BPSO and BGWO, optimizing the system configuration while maintaining observability. A trade-off analysis was performed to examine the trade-off between redundancy and PMU count, showing that increasing the number of μ-PMUs improves system resilience. Voltage and current channels were measured from the optimized placements to ensure accurate voltage measurement in all case studies. Subsequently, the Weighted Least Squares algorithm was applied for voltage estimation, serving as a peripheral to the main objective of the optimal μ-PMU placement. Voltage estimation was conducted under three noise levels: 0.01 STD for basic analysis and 0.02 and 0.04 STD to observe the impact of varying measurement noise. The results highlight that higher μ-PMU placements improve voltage estimation accuracy, particularly under higher noise levels. Statistical analysis confirms that BGWO outperforms BPSO in terms of computational efficiency, stability, and convergence, especially in large-scale systems. By enhancing grid monitoring and state estimation, this research directly contributes to the development of more resilient and efficient power networks, which is a fundamental prerequisite for integrating renewable energy sources and advancing overall power system sustainability. This research emphasizes the balance between cost and reliability in μ-PMU placement and provides a comprehensive methodology for state estimation in modern power systems.

Suggested Citation

  • Asjad Ali & Noor Izzri Abdul Wahab & Mohammad Lutfi Othman & Rizwan A. Farade & Husam S. Samkari & Mohammed F. Allehyani, 2025. "Optimal µ-PMU Placement and Voltage Estimation in Distribution Networks: Evaluation Through Multiple Case Studies," Sustainability, MDPI, vol. 17(24), pages 1-55, December.
  • Handle: RePEc:gam:jsusta:v:17:y:2025:i:24:p:11036-:d:1814173
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/2071-1050/17/24/11036/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/2071-1050/17/24/11036/
    Download Restriction: no
    ---><---

    More about this item

    Keywords

    ;
    ;
    ;
    ;
    ;
    ;
    ;

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jsusta:v:17:y:2025:i:24:p:11036-:d:1814173. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager The email address of this maintainer does not seem to be valid anymore. Please ask MDPI Indexing Manager to update the entry or send us the correct address (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.