IDEAS home Printed from https://ideas.repec.org/a/gam/jsusta/v16y2024i4p1638-d1340004.html
   My bibliography  Save this article

Research on Multi-Point Monitoring Data Grid Model and Inversion Positioning Method for Gas Leakage in Oil and Gas Stations

Author

Listed:
  • Ge Meng

    (School of Civil Engineering and Architecture, Wuhan Institute of Technology, Wuhan 430074, China)

  • Hao Hu

    (School of Civil Engineering and Architecture, Wuhan Institute of Technology, Wuhan 430074, China)

Abstract

The safe and stable operation of oil and gas stations makes a positive contribution to the stability and reliability of the natural gas supply. In order to reduce the impact of leakage and diffusion accidents in the station, it is necessary to develop an effective method to monitor and locate the leakage source quickly and accurately. This study proposes a multi-point monitoring data grid model to achieve the full-coverage monitoring of oil and gas stations. In addition, on this basis, a leakage source inversion positioning model is established to realize the leakage positioning of the station. A field experiment was carried out with an oil and gas station as an example. The results show that the optimal layout of points needs to consider the influence of environmental factors, confirmed by computational fluid dynamics (CFD) simulation. The optimized data interpolation not only reduces the cost of the monitoring point layout. In addition, through the comparison of multi-objective optimization algorithms and a robustness test, it can be found that the convergence efficiency and accuracy of the inversion positioning algorithm in this study have been greatly improved. Compared with the manual auxiliary positioning method, this method effectively solves the problem of leakage monitoring and positioning of oil and gas stations, and can achieve the purpose of leakage risk monitoring and “reducing cost and increasing efficiency”.

Suggested Citation

  • Ge Meng & Hao Hu, 2024. "Research on Multi-Point Monitoring Data Grid Model and Inversion Positioning Method for Gas Leakage in Oil and Gas Stations," Sustainability, MDPI, vol. 16(4), pages 1-24, February.
  • Handle: RePEc:gam:jsusta:v:16:y:2024:i:4:p:1638-:d:1340004
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/2071-1050/16/4/1638/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/2071-1050/16/4/1638/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jsusta:v:16:y:2024:i:4:p:1638-:d:1340004. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.